Thermoplan BLACK&WHITE 3 FOX2 Technical Manual page 10

Advertisement

User messages
Text message
v.
RF temp
too high
w.
Flow error
x.
Change filter
y.
Piston Error
z.
NTC Coffeeboiler
open
aa.
PM required
© 2010 Thermoplan AG, Subject to change
Technical Manual
Reason / solution
• Info message, refrigerator temp is higher than 4 °C
if on short notice, only as info / check if refrigerator door is closed
if permanent, check refrigerator for function (place hand on left inner side)
Check the refrigerators temperature sensor
• Flow meter impeller is not rotating
Obstruction inside flow meter or water path
• Flow meter sensor does not read magnetic contacts on impeller
Pins on electrical plug are not connected or corroded
• No water pressure on machine
Check water pressure
• Change hydraulic module
• Water filter is saturated.
Dispensing of products still possible.
Change water filter
Reset counter
• Obsturcted 24V piston motor
Check brew chamber and shaft for contamination or obstruction
• 24V piston motor has no impulse
• 24V piston motor has no 24VDC
• Change mechanical module
• CPU does not read NTC probe signal
Check for defective wiring on hydraulic module NTC probe
Note: „NTC Coffeeboiler Open" message automatically appears on the display
when the machine is on and the hydraulic module is removed.
• Change hydraulic module
• Machine has reached a preprogrammed number of brew cycles
Perform preventative maintenance as required
Reset counter