Trouble-Shooting; Control Panel Technical Specifications - jablotron JA-80K-US Installation Manual

Table of Contents

Advertisement

16. Trouble-shooting

Problem
The control panel is not in service
mode after being powered up.
It is impossible to enroll a wireless
device to the control panel.
The keypad unit indicates a fault
A motion detector triggers false alarms
for no apparent reason.
The wireless keypad does not indicate
entrance delays by beeping.

17. Control panel technical specifications

Power supply
Backup-battery
Backup power output
Number of wireless device addresses
Number of hard-wired inputs
External warning output EW*
Internal warning output IW*
Programmable outputs*
Event memory
Communications frequency
Security grade
Operating environment
Complies with
Radio emissions
EMC
Electrical safety
Can be operated according to
FCC ID: VL6JA80K
* these signals are also transmitted wirelessly to AC and UC receiver modules.
Jablotron Ltd. hereby declares that the JA-80K-US is in compliance with the essential requirements and other relevant provisions of
Directive 1999/5/EC and complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications no expressly approved by Jablotron could void the user´s authority to operate the equipment.
The original of the conformity assessment can be found at www.jablotron.com, Technical Support section.
Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to
the producer after use.
Installation manual: Oasis security system JA-80K
Possible causes
The control panel does not have factory-default settings.
The device's location is unsuitable, the control panel antenna is
disconnected, the device's battery was incorrectly installed, the
control panel is not in enrollment mode, the device is too near to
the control panel (it should be at least 2 meters away).
Press the ? key to see the cause.
Animals are moving in the protected area (mice etc), sudden
changes in temperature, significant air movements, movement of
objects having a temperature close to 37° C (e.g. curtains moving
above a radiator)
If the keypad is only battery-powered, then it turns off 20
seconds after the last time a key was pressed. To indicate
entrance delays, first wake it up.
110-120 V / 50-60 Hz, max 0.1 A, CLASS PROTECTION II
12 V, 1.3 or 2.2 Ah, typical battery lifetime approx. 5 years
maximum continuous load 0.4 A, intermittent load 1 A for 15 min's max.
50
2, double balanced inputs, with triggering and tamper functions, programmable section assignment and
reactions
switchable relay contact max. 1A/60V
switching to GND, max. 0.5A
PGX, PGY max. 0.1 A, switching to GND, programmable function
255 latest events, including date and time stamping
868 MHz
2 according to EN 50131-1, EN 50131-6, and EN 50131-5-3
II. internal (-10 to +40° C) - compliant with EN 50131-1
CISPR 22, ANSI C63.4
ETSI EN 300 220
EN 50130-4, EN 55022
EN 60950-1
ERC REC 70-03, FCC Part 15
control panel dimensions
Reset the control panel.
Check and fix it.
React according to the cause displayed.
Change the location of the detector, select a higher
immunity in the detector, use an optional pet lens in
the detector, program alarms confirmed by two
detectors in the control panel.
Install an ordinary magnetic sensor to the entrance
door, wiring it to the keypad input so that opening
the door wakes up the keypad and reports to the
control panel. Alternatively, power the keypad with
an AC adaptor to prevent sleep mode or install an
indoor wireless siren type JA-80L to generate
entrance delay beeps.