Technical Data; General Technical Data - FIBRO 2480.00.32.71 Instruction Manual

Nitrogen compact booster
Table of Contents

Advertisement

Technical data

3
TECHNICAL DATA
3.1

General technical data

Name
Inlet pressure
Compressed driving air
Calculated operating pressure
(at 6 bar air drive pressure)
Pressure relief
Transmission
Piston displacement
Medium supply performance*
*The feed performance is depending on the air drive pressure and from the inlet pressure.
Max. operating temperature
Weight
Dimensions (WxDXH)
Noise emission
Connections
Pressurized air
Nitrogen inlet
Nitrogen outlet
Instructions manual Nitrogen Compact Booster
Value
30 - 200 bar
minimum 1 bar to 6 bar maximum
Pressurised air purified and oiled
192 bar (+ Residual bottle pressure)
400 bar
1 : 32
3
11,6 cm
280 NL/min
60 °C
approx. 7,2 kg
160x380x345 mm
< legally permissible peaks
G 1/4"
Hose line DN4, length 1 m
for N2-bottles 200 bar
Bottle connection W 24,32 x 1 1/4"
for N2-bottles 200 bar
15/38