6. Shut-off valve has to be closed at the filling hose.
7. Nitrogen bottle has to be opened at the turn knob of the bottle valve.
8. Switch on machine (switch on lever has to be turned left by 90°).
9. Adjust at the bottle pressure regulator the maximum filling pressure (right = pressure in-
NOTICE
Damage to the valve in the gas pressure spring
 Slowly open the shut-off valve on the filling hose.
 Carefully allow nitrogen to flow in.
10. Shut-off valve has to be opened slowly at the filling hose.
The permissible filling pressure (a) is imprinted on the gas spring.
24/38
crease, left = pressure reduction).
7.
a) The right manometer at the bottle pressure regulator and the manometer at the filling
and control fitting show the actual pressure in the gas spring.
8.
6.
Instructions manual Nitrogen Compact Booster
Operation
9.
xxxxx
xxxxx
xxxxxx
xxx bar
a
xxxxx
xxxxx
xxxxxx
xxx bar
10.