Operation; Important Safety Instructions; Workstations For Operating Personnel; Prior To Commissioning - FIBRO 2480.00.32.71 Instruction Manual

Nitrogen compact booster
Table of Contents

Advertisement

Operation

6
OPERATION
6.1

Important safety instructions

Impermissible values and setting.
The permissible maximum values for the operation of the machine which may not be exceeded.
 Operation only on nitrogen bottle with maximum 200 bar internal pressure.
 Compressed driving air maximum 6 bar.
 Check values and settings prior to commissioning.
 Nitrogen exits at the over pressure valve. Risk of injury.
Please ensure when operating the machine that the
6.2

Workstations for operating personnel

The workplace to operate is directly at the machine. Operational parts are the startup valve at
the control bottle pressure regulator and the control at the filter and control valve.
6.3

Prior to commissioning

A visual inspection has to be carried out prior to commissioning the machine. The following has
to be checked and ensured:
Instructions manual Nitrogen Compact Booster
WARNING!
machine is ready assembled. (see chapter 5.3 "Assembling the machine" on page 19).
operating staff has been informed about the proper conduct in the event of a machine failure.
machine is only operated by staff that has been trained, instructed and authorised to do so.
These persons have to know the instructions and act accordingly.
machine is only operated according to its intended use (see chapter 1.2 "Intended use" on
page 5).
operating instructions of the operator are adhered to.
there is no damage to the machine.
that the pressurised air supply is connected and operational.
that the machine is connected to a nitrogen bottle.
the valve of the nitrogen bottle is connected.
that the start-up valve of the machine is connected.
21/38