Memory Function; Important Notices; Error Codes - LaserLine LaserRange-Master i5 Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11

Memory function:

The device has 50 storage locations.

Important notices

– The laser points to the location that will be measured.
No objects may get into the laser's line of measurement.
– The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
– The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
– The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
– In unfavourable conditions, e.g. with poorly reflecting surfaces,
the maximum deviation may be greater than 3 mm.
– Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
– Measurements made through glass (window panes) can falsify
measurement results.
– An energy-saving function switches the device off automatically.
– Clean with a soft cloth. Water may not be allowed to penetrate
the housing.

Error codes:

Err10:
Replace the battery
Err11:
Data transfer error
Err14:
Calculation error
Err15:
Outside the measuring range
Err16:
Received signal too weak
Err18:
Tilt sensor calibration error
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The measuring device should be calibrated and tested on a regular
basis to ensure it is accurate and working properly. We recommend the
measuring device is calibrated every 1 - 2 years. If necessary, contact your
distributor or the UMAREX-LASERLINER service department.
16