User Manual
Article NO: RGB-RD-UM-SubitoNX S2/S4-E000
1
Version NO: V1.0

Advertisement

Table of Contents
loading

Summary of Contents for RGBlink SubitoNX S2

  • Page 1 SubitoNX S2/S4 User Manual Article NO: RGB-RD-UM-SubitoNX S2/S4-E000 Version NO: V1.0...
  • Page 2: Table Of Contents

    3.4 Parameter Adjustment of Receiver Card and Sender Card............ 17 3.5 Upgrade..........................21 Chapter 4 Ordering Codes........................23 4.1 Product........................... 23 Chapter 5 Support ..........................24 5.1 Contact Us..........................24 Chapter 6 Appendix..........................25 6.1 Specification........................... 25 6.2 Terms & Definitions........................ 25 6.3 Revision History........................32 SubitoNX S2/S4 User Manual...
  • Page 3: Declarations

    RGBlink. If the purchaser or a third party carries out modifications or repairs on goods delivered by RGBlink, or if the goods are handled incorrectly, in particular if the systems are commissioned operated incorrectly or if, after the transfer of risks, the goods are subject to influences not agreed upon in the contract, all guarantee claims of the purchaser will be rendered invalid.
  • Page 4: Operators Safety Summary

    To protect users from electric shock, ensure that the chassis connects to earth via the ground wire provided in the AC power Cord. The AC Socket-outlet should be installed near the equipment and be easily accessible. SubitoNX S2/S4 User Manual...
  • Page 5 Site Preparation The environment in which you install your product should be clean, properly lit, free from static, and have adequate power, ventilation, and space for all components. SubitoNX S2/S4 User Manual...
  • Page 6: Chapter 1 Your Product

    Chapter 1 Your Product 1.1 In the Box DVI-DVI Cable USB Cable Power Cord Note: Power Adapter supplied as British and Australian standards. SubitoNX S2/S4 User Manual...
  • Page 7: Product Overview

    1.2 Product Overview SubitoNX S2 supports two network port,with a maximum load capacity of 1.31million pixels;SubitoNX S4 supports four network output, with a maximum load capacity of 2.35 million pixels.Both support resolution up to 2048×1152@60 or custom resolution. SubitoNX S2...
  • Page 8: Front Panel

    1.2.1 Front Panel Take SubitoNX S4 as an example Item Function Signal Indicator Successful connection:flash green;No signal:static green Power Indicator Static red Power Switch Turn on/off the device SubitoNX S2/S4 User Manual...
  • Page 9: Rear Panel

    Load capacity up to 2.35m pixels  H MAX pixels:3840 pixels  V MAX pixels:1920 pixels  3.Audio Connectors Connector Number Description 3.5mm Audio Jack Connect audio input 4.Communication Connectors Connector Number Description Connect control device SubitoNX S2/S4 User Manual...
  • Page 10: Dimension

    1.2.4 Dimension Following is the dimension of SubitoNX S4 for your reference: Dimension of SubitoNX S2/S4:178.6mm×167.4mm×39.1mm SubitoNX S2/S4 User Manual...
  • Page 11: Chapter 2 Install Your Product

    Chapter 2 Install Your Product Since SubitoNX S2 and SubitoNX S4 only have the difference in the number of output network ports, other functions and operations are the same.Therefore, SubitoNX S4 is taken as an example to introduce in the following chapters.
  • Page 12: Chapter 3 Use Your Product

    Monitor:Resolution must be 1680×1050 pixel or above(it can not display normally if the resolution is lower than 1680×1050) CPU:i5 and above 1. Double click ,it will pop-up the installer language box, select the language, for example, select <English>, and click <OK> to confirm. 2. Click <Next> to install SubitoNX S2/S4 User Manual...
  • Page 13 3. Click <Browse...>to select the XPOSE software install location Click <Install> 4. During installation, it will pop up the window of Install Shield Wizard for Virtual Com port 5. Click <Next> SubitoNX S2/S4 User Manual...
  • Page 14 6. Then click <Install>, as shown in the figure 7. Click <Finish> and complete the installation, as shown in the figure below 8. Click <Finish> and is ready to run the XPOSE software SubitoNX S2/S4 User Manual...
  • Page 15: Log In Xpose

    Note:The email shall be invalid and complete otherwise Registration&Activation code cannot be received. 2. Click Activate and scan the QR code An email from ill be sent RGBlink Registrations w to the Register email address. 3. Type in the activate code and confirm. SubitoNX S2/S4...
  • Page 16: Fine Device

    3.3 Fine Device 1. Click to enter <System Setting>interface. 2. New version of XPOSE 2.0 is blank default in Find Device. Users are supposed to choose the device needed in System Setting. SubitoNX S2/S4 User Manual...
  • Page 17: Parameter Adjustment Of Receiver Card And Sender Card

    Devices>,then GX4L will show in the main interface. 3.4 Parameter Adjustment of Receiver Card and Sender Card Click the LAN port in rear panel Click <Library>-<Parameters Set> to enter the interface of parameter adjustment SubitoNX S2/S4 User Manual...
  • Page 18 Note:After setting the sending card, it is necessary to click <Save to the sending card>, otherwise the previous setting will be lost after power off and restarting. 3. Click <Receiving Card> to enter the interface as shown in the left figure. 4. Click<Smart Settings> to set receiving card. SubitoNX S2/S4 User Manual...
  • Page 19 1/2/3/4 to change the display state according to the observation of the LED screen. For example,click <1>and observe the color of LED screen,and select <red> if the LED screen shows red. After all 4 states being done,click <next> SubitoNX S2/S4 User Manual...
  • Page 20 <Send to receive card>and observe the change of the screen. ④ Save to the receive card:After debugging,click <Save to the receiving card>and the data will not be lost after power off and restart. SubitoNX S2/S4 User Manual...
  • Page 21: Upgrade

    2. Type in password <admin> or 168. ① Select <Send Card> ② View the version ③ Load corresponding send card ④ Click <upgrade> Note:during the upgrade process, do not unplug the serial port to prevent communication disconnection. SubitoNX S2/S4 User Manual...
  • Page 22 ① Select <Receive Card> ② View the version ③ Load corresponding send card ④Click <upgrade>,do not unplug the serial port to prevent communication disconnection SubitoNX S2/S4 User Manual...
  • Page 23: Chapter 4 Ordering Codes

    Chapter 4 Ordering Codes 4.1 Product 880-1002-01-0 SubitoNX S2 880-1004-01-0 SubitoNX S4 SubitoNX S2/S4 User Manual...
  • Page 24: Chapter 5 Support

    Chapter 5 Support 5.1 Contact Us SubitoNX S2/S4 User Manual...
  • Page 25: Chapter 6 Appendix

    0.5kg Dimension 178.6mm×167.4mm×39.1mm *SubitoNX S2 has 2 LAN ports with capacity of 2.31m pixels.Other parameters are consistent with that of SubitoNX S4 6.2 Terms & Definitions ●RCA: Connector used primarily in consumer AV equipment for both audio and video. The RCA connector was developed by the Radio Corporation of America.
  • Page 26 Released on September 4, 2013 increases the maximum bandwidth to 18.0 Gbit/s. Other features of HDMI ●HDMI 2.0: 2.0 include up to 32 audio channels, up to 1536 kHz audio sample frequency, the HE-AAC and DRA audio standards, improved 3D capability, and additional CEC functions. SubitoNX S2/S4 User Manual...
  • Page 27 GBIC, and CATV. SC is one of the most popular options, as its simplicity in design comes along with great durability and affordable prices. ●LC:(Lucent Connector) is a small factor connector (uses only a 1.25mm ferrule diameter) that has a snap coupling SubitoNX S2/S4 User Manual...
  • Page 28 PAL TV set. PAL, is widely used in needed on a PAL TV set. PAL, is widely used in Western Europe, Australia, Africa, Middle East, and Micronesia. PAL uses 625-line, 50-field (25 fps) composite colour SubitoNX S2/S4 User Manual...
  • Page 29 Transmission. ●H.264: Also known as AVC (Advanced Video Coding) or MPEG-4i is a common video compression standard. H.264 was standardized by the ITU-T Video Coding Experts Group (VCEG) together with the ISO/IEC JTC1 Moving Picture SubitoNX S2/S4 User Manual...
  • Page 30 ●Gamma: The light output of a CRT is not linear with respect to the voltage input. The difference between what you should have and what is actually output is known as gamma. SubitoNX S2/S4 User Manual...
  • Page 31 ●EDID: Extended Display Identification Data. EDID is a data structure used to communicate video display information, including native resolution and vertical interval refresh rate requirements, to a source device. The source device will then output the provided EDID data, ensuring proper video image quality. SubitoNX S2/S4 User Manual...
  • Page 32: Revision History

    Release Sylvia All information herein is Xiamen RGBlink Science & Technology Co Ltd. excepting noted. is a registered trademark of Xiamen RGBlink Science & Technology Co Ltd. While all efforts are made for accuracy at time of printing, we reserve the right to alter otherwise make change without notice.