jablotron OASiS JA-82KRC Installation Manual page 9

Table of Contents

Advertisement

Radio interference indication
Radio communication supervision
RESET enabled
Master control panel enrollment to a sub control
panel for setting (arming) control
Master code reset
Measuring signal strength
Enrolling the control panel to UC, AC or a sub
control panel
Setting (arming) without an access code
Triggered detector indication
by text on the keypad display
Confirmation of intruder alarms
In this mode, the triggering of an intruder detector in a set
(armed) section will only be recorded to the memory as an
unconfirmed alarm and if then followed by the activation of any
other intruder detector within 40 minutes, an alarm will be
triggered. If the first triggered detector has a DEL reaction and
it is not confirmed by any other detector, it will not trigger an
alarm after the entrance delay has expired.
Exit delay beeps
Exit delay beeps while partially arming
Entrance delay beeps
Setting (arming) confirmation by wired-siren chirp
Siren always sounds during audible alarms
Wireless-siren alarms enabled (IW & EW)
Auto-bypass user approval via the ∗ key
If a detector is active during setting (arming), the system will
automatically bypass it (them), immediately (390), or after
keying in ∗ (391)
Final-door detectors
If this function is used, then Exit & Entrance delay settings are
multiplied by 30s. A triggered final-door detector extends the
exit delay, de-triggering of the last final-door detector ends the
exit delay.
Partial setting (arming) or system splitting
Automatic Summer Time (Daylight Saving Time)
Tamper-signal differential indication -
Tamper alarm in response to an increase in the
number of triggered tamper sensors
Operating the PG outputs using ∗8 and ∗9
Permanent alarm status display for a set system
Tamper alarm if unset (disarmed)
Recording PG output activation to memory
Installation manual: OASiS security system JA-82KRC
26x
261 = YES
271 = YES
27x
28x
281 = YES
290
The sequence triggers
enrollment.
Returns master code to 1234
291
298
Activates measurement
299
The sequence triggers
enrollment.
30x
301 = YES
31x
311 = YES
321 = YES
32x
331 = YES
33x
34x
341 = YES
351 = YES
35x
36x
361 = YES
37x
371 = YES
381 = YES
38x
39x
391 = YES
0=none, 1=detectors 01 to 05,
65x
2=detectors 46 to 50
0 = unsplit system
66x
1 = partial setting (A, AB, ABC)
2 = split system A, B & common
section C (set if A & B are set)
680x
6801 = YES
681x
ignore permanently
6811 =
triggered tamper sensors, i.e.
only react to an increase in
the number of triggered
tamper sensors
react with a tamper
6810 =
alarm to all triggered tamper
sensors
682x
6821 = YES
6831 = YES
683x
684x
6841 = YES
6851 = YES
685x
9 / 21
260 = NO
NO
30s or longer
270 = NO
NO
280 = NO
YES
(Un)setting the master control
panel will (un)set the sub control p.
The sub c. panel must be in
enrollment mode.
It has no effect on other codes and
it is recorded in the control panel
memory
arrow keys scroll addresses,
# halts measurement.
see 12.10
300 = NO
YES
by keying: A, B, ABC,
∗1, ∗2, ∗3, ∗4
allows the display
310 = NO
YES
of open windows &
doors,
to view details
press ?
320 = NO
An alarm can be
NO
confirmed by any
other intruder
detector in any
section which is set
(armed).
330 = NO
YES
The last 5 s faster
340 = NO
NO
The last 5 s faster
350 = NO
YES
IW terminal only
360 = NO
NO
NO = siren only
370 = NO
YES
sounds if the system
is completely set
(armed)
380 = NO
YES
390 = NO
NO
to confirm auto-
bypass while exiting
Service mode press #
twice
x = 0
If multiple F. door
detectors are used,
then triggered
state=any of them,
non triggered state=all
of them
unsplit
Changes internal
6800 = NO
NO
clock + 1h on Apr.1 &
-1h on Nov.1
Suppresses the
X = 0
indication of
permanently triggered
tamper sensors
if yes then arrow keys
6820 = NO
YES
can also operate PGX
suppresses the 3min.
6830 = NO
NO
display timeout
6840 = NO
NO
6850 = NO
YES
(linked to 33x setting)
MKH51100_OS2