BWT PERMAQ PRO 1810 Installation And Operating Instruction

BWT PERMAQ PRO 1810 Installation And Operating Instruction

Reverse osmosis plant

Advertisement

Quick Links

Installation and operating Instruction
EN
®
BWT PERMAQ
PRO 1810-1820
Reverse Osmosis Plant

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PERMAQ PRO 1810 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BWT PERMAQ PRO 1810

  • Page 1 Installation and operating Instruction ® BWT PERMAQ PRO 1810-1820 Reverse Osmosis Plant...
  • Page 3: Table Of Contents

    POSITIONING OF THE PLANT ..................5 WATER QUALITY ......................5 WATER CONNECTIONS....................6 ® Connection of soft water to the BWT PERMAQ Pro ..............6 Connection of permeate hose ....................6 Connection of permeate (desalinated water for consumption) ............. 6 Connection of outlet hose (concentrate) ...................
  • Page 4: General Information

    This installation and operating intervals are not met. removed from the manual applies Your BWT PERMAQ® Pro 1800 water. ® PERMAQ Pro 1800 total desal- plant is constructed in a com- Feed water: Is the water which ination plant.
  • Page 5: Positioning Of The Plant

    If there is no floor drain near quality of the treated water will (option) have to be installed too. Water quality (contact BWT for technical advice) Content Symptom Preventive action Can in some cases be micro-filtrated TOC, BOC and Can cause slimy as well as firm hard film.
  • Page 6: Water Connections

    *Fuse: 16 Amp reservoir (option) and be led on the outlet valve. See also electric diagram under to the flow meter of the BWT  After completed flushing, encl. 13.3 ® PERMAQ Pro (outlet top).
  • Page 7: Adjustment Of Outlet Amount

    10 °C. water) below 20 µS/cm (conductivity E.g. if the feed water tempera- meter is available as optional ture is 8 °C, for an BWT equipment). PERMAQ ® Pro 1810 it means ®...
  • Page 8: Automatic Functions

    3 days or longer, and by Maintenance intervals ground water the membranes compiled by updating BWT must be preserved at a standstill ® PERMAQ Pro’s operating lasting 7 days or longer.
  • Page 9: Troubleshooting

    Troubleshooting This section deals with the problems that may arise on the plant. 9.2.1 The plant capacity has dropped...
  • Page 10: The Quality Of The Treated Water Is Higher Than 20 Μs/Cm

    9.2.2 The quality of the treated water is higher than 20 µS/cm 9.2.3 Alarm: Low feed water pressure...
  • Page 11: Alarm: Transport Pump

    9.2.4 Alarm: Transport pump 9.2.5 Indication: Level low...
  • Page 12: Alarm: Level High

    9.2.6 Alarm: Level high 9.2.7 The plant is not operating 9.2.8 Alarm: The transport pump stops and starts Check AQUA Flex’s manual chapter 6. Troubleshooting 9.2.9 Hard water is measured at the soft-water tap Check softening plants manual for troubleshooting...
  • Page 13: Survey Of Alarm Conditions

    LED’s are lit LED’s flashes slowly (½ Hz) LED’s flashes rapidly (5 Hz) BWT PERMAQ ® Pro emits beep tone at Alarm condition (Nothing is working), which can only be neutralised by rectifying the fault, then switching the plant OFF for 5 seconds and switching ON again.
  • Page 14: Settings

    It is possible to adjust the various time settings for Start, Stop and Alarm, plus insert a start-up delay of the pump. Use of DIP-switch: No. 1 High-pressure pump No. 2 Transport pump No. 3 Selection of BWT PERMAQ ® Pro 1800 model No. 4-6 Transport pump Factory settings DIP-switch F3 – Fuse (Transport pump) F2 –...
  • Page 15: Technical Specification

    10. TECHNICAL SPECIFICATION 10.1 Technical specifications BWT PERMAQ Pro 1800 ® Tag number Description Type/data High-pressure pump 2.2 kW, 4.45A High-pressure pump 2.2 kW, 4.45A P2 (option) Transport pump 0.85 kW, 4.5A / 1.2 kW, 4.8A FI 1 Flow meter Ø32 PVC...
  • Page 16: Functional Description

    4" membrane membranes pipe from your usual supplier or 2. New capacity on the plant, from BWT. flow meter FI1(13.7 Spare The membrane can now be parts drawing Pos. 9) pulled out of the membrane 3.
  • Page 17: Annex

    13. ANNEX 13.1 P&I Diagram 13.2 Layout drawings 13.3 Wiring diagram 13.4 Start-up test 13.5 Operating journal 13.6 Spare-parts list BWT PERMAQ ® Pro 1800 13.7 Spare-parts drawing 13.8 Options 13.9 Declaration of conformity...
  • Page 18 13.1 P&I Diagram...
  • Page 19: Layout Drawings

    13.2 Layout Drawings...
  • Page 20: Wiring Diagram

    13.3 Wiring Diagram...
  • Page 23: Start-Up Test

    NO, the problem does not concerns the plant or the installation The plant - we mean only the part of the whole installation which was delivered by BWT (i.e only the plant). The installation - we mean the piping etc. leading to the plant.
  • Page 24: Operating Journal

    13.5 Operating Journal Maintenance intervals should be performed as described below in the Operating Journal. Replacement frequency ® of wearing parts showed in section 13.6 Spare Parts List BWT PERMAQ Pro 1800.
  • Page 25: Spare Parts List Bwt Permaq Pro 1800

    ¾” Pressure hose, L=210 mm 451404180 Miscellaneous 6 mm Plastic hose 454001006 3 years 14 mm Plastic hose 454001014 3 years Spare parts for options Sensor (conductivity meter) 452536007 Conductivity meter 452525000 * Contact your local BWT dealer for detailed information.
  • Page 26: Spare Parts Drawing

    13.7 Spare Parts Drawing...
  • Page 27: Options

    13.8 Options ® For BWT PERMAQ Pro 1800 reverse osmosis units you can select between following options, contact **BWT Sales for further information. 13.8.1 Option 1 - Hose Connector Kit BWT carry complete assembly kits (hose kits) for BWT Part No.: 656525800 ®...
  • Page 28: Option 7 - Conductivity Meter Including A 4-20 Ma Outlet

    Option 9 - Mixed-bed If a water quality < 0,5 µS/cm is required, we recom- Part No.: ** mend a BWT HOH Demi Mix (a mixed-bed unit) for post-treatment of the reverse osmosis water. 13.8.10 Option 10 - Upgrade Kit...
  • Page 29: Declaration Of Conformity

    EC Declaration of Conformity for Machinery Directive 2006/42/EC, Annex II, A Low Voltage Directive EMC Directive BWT HOH A/S Geminivej 24 - DK-2670 Greve tel.: +45 43 600 500 - fax: +45 43 600 900 bwt@bwt.dk - www.bwt.dk herewith declares that: BWT PERMAQ ®...
  • Page 30 Notes ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________...
  • Page 31 Notes ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________...
  • Page 32 Fax: +33 1 4922 45 45 E-Mail: office@bwt.at E-Mail: bwt@bwt.de E-Mail: info@cillichemie.com E-Mail: bwt@bwt.fr BWT Belgium NM. BWE Česká Republika s.r.o. BWT Polska Sp. z o.o. BWT Hungária Kft. Leuvensesteenweg 633 Lipovo 196 -Cestlice ul. Polczyhska 116 Keleti út. 7. CZ-251 01 Říčany...

This manual is also suitable for:

Permaq pro 1820

Table of Contents