Philio PAN15-2 Manual

Philio PAN15-2 Manual

Smart energy plug in switch

Advertisement

Quick Links

PAN15-1/-2
Smart energy plug in switch
This plug-in ON/OFF switch PAN15 is a security enabled wireless switch, based on
Z-Wave Plus technology. Z-Wave Plus
TM
Plus
logo can also be used with it regardless of the manufacturer, and can also be
used in other manufacturer's Z-Wave
the connected load is possible with other manufacturer's wireless Controller. Each
switch is designed to act as a repeater. Repeaters will re-transmit the RF signal to
ensure that the signal is received by its intended destination by routing the signal
around obstacles and radio dead spots. Because PAN15 supports Security Command
Class, it can learn with Secured controller. Its functionality and supported command
classes is identical when included as a secure and non-secure device.
This plug-in ON/OFF switch is able to detect instance wattage (1560W/UL/TW/JP)
and overload current (14.5A) of connected lights or appliances. When detecting
overload state, the Switch will be disabled and its On/Off button will be lockout of
which LED will flash quickly. However, unplug and re-connect the switch will reset its
overload condition to normal status.
TM
Adding to Z-Wave
Network
In the front casing, there is an On/Off button with LED indicator which is used to toggle
P
TM
enabled devices displaying the Z-Wave
TM
enabled networks. Remote On/Off control of
switch on and off or carry out inclusion, exclusion, reset or association. When first
power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second
intervals. It implies that it has not been assigned a node ID and start auto inclusion.
Auto Inclusion
The function of auto inclusion will be executed as long as the switch does not have
Node ID and just plug the switch into a wall outlet.
Note: Auto inclusion timeout is 2 minute during which the node information of explorer
frame will be emitted once several seconds. Unlike "inclusion" function as shown in
the table below, the execution of auto inclusion is free from pressing the On/Off button
on the Switch.
The table below lists an operation summary of basic Z-Wave functions. Please refer to
the instructions for your Z-Wave
function, and to include/exclude/associate devices
Function
Description
No node ID
The Z-Wave Controller does not allocate
a node ID to the Switch.
Inclusion
1.Put your Z-Wave controller into
inclusion mode by following the
instructions provided by the
controller manufacturer.
2. Pressing On/Off button three times
within 2 seconds will enter inclusion
mode.
Exclusion
1.Put your Z-Wave controller into
exclusion mode by following the
instructions provided by the
controller manufacturer.
1.
Pressing On/Off button three times
within 2 seconds will enter exclusion
mode.
Node ID has been excluded.
1
TM
Certificated Primary Controller to access the Setup
Annotation
LED 2-second on, 2-second
off
LED 0.5s On, 0.5s Off (Enter
auto inclusion)

Advertisement

Table of Contents
loading

Summary of Contents for Philio PAN15-2

  • Page 1 switch on and off or carry out inclusion, exclusion, reset or association. When first PAN15-1/-2 power is applied, its LED flashes on and off alternately and repeatedly at 0.5 second intervals. It implies that it has not been assigned a node ID and start auto inclusion. Smart energy plug in switch Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have...
  • Page 2: Choosing A Suitable Location

    Reset Pressing On/Off button three times Use this procedure only in Choosing a Suitable Location within 2 seconds will enter inclusion the event that the primary mode. controller is lost or Within 1 second, press On/Off otherwise inoperable. 1. Do not locate the Switch facing direct sunlight, humid or dusty place. button again for 5 seconds.
  • Page 3 ON:[Command Class Switch Binary, Switch Binary Report, Value Binary Switch Get Command:[Command Class Switch Binary, Switch Binary =255(0xFF)] Get] OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] Binary Switch Report Command: Report OFF:[Command Class Switch Binary, Switch Binary Report, Value 2-1-2 Instant Power Consumption vary over 5% report =0(0x00)] When the power consumption of load vary over 5%, it will send Meter report to the...
  • Page 4 2-2-4 AC load Voltage (V) When receiving Meter Get Command, it will report Meter Report Command to the Example: node. Scale = 0x02 (W) Precision = 1 Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)] Size = 4 Bytes (W) Meter Value 1 = 0x00 (W) Meter Report Command: Meter Value 2 = 0x00 (W)
  • Page 5 Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)] Watt Meter Report Period: Meter Report Command: If the setting is configured for 1hour (set value =720), the PAN15 will report its [Command Class Meter, , , , Meter Report, , , , Rate Type = 0x01, , , , Meter Type = 0x01, , , , Precision = 2,...
  • Page 6: Troubleshooting

    3-7 LED indication mode : PAN15 is based on 500 series SoC and supports Firmware Update Command Class, 3-7-1 Show Switch State:When switch is on, LED is on. When switch is off, LED is it can receives the updated firmware image sent by controller via the Z-wave RF off.
  • Page 7: Specification

    2. The switch is protected The Switch LED 1. Not carry out 1. Carry out association Company of License Holder:Philio Technology Corporation illuminating, but the association 2. Wait for a while to re-try Detector cannot control 2. Same frequency Address of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New...

This manual is also suitable for:

Pan15-1

Table of Contents