Standard Labor Guidelines To Repair or Replace Parts on Delfield Equipment
Improper servicing or service not performed by an authorized service agent could result in an explosion or damage.
Advice and recommendations given by Delfield Service Technicians do not constitute or guarantee any special coverage.
• A maximum of 1-hour is allowed to diagnose a defective component.
• A maximum of 1-hour is allowed for retrieval of parts not in stock.
• A maximum travel distance of 100 miles round trip and 2-hours will be reimbursed.
• Overtime, installation/start-up, normal control adjustments, general maintenance, glass breakage, freight damage, and/or
correcting and end-user installation error will not be reimbursed under warranty unless pre-approved with a Service Work
Authorization from Delfield. You must submit the number with the service claim.
LABOR OF 1-HOUR IS ALLOWED TO REPLACE:
• Compressor Start Components and Overload Protector
• Door Hinges, Locks, and Gaskets
• Evaporator/Condenser Fan Motor and Blade
• Thermostat
LABOR OF 2 HOURS TO REPLACE:
• Defrost Element
• Locate/Repair Leak
LABOR OF 3 HOURS TO REPLACE:
• Capillary Tube
• Condenser or Evaporator Coil
LABOR OF 4 HOURS TO REPLACE
• Compressor, this includes recovery of refrigerant and leak check.
$55.00U.S. maximum reimbursement for refrigerant recovery (includes recovery machine, pump, torch, oil, flux, minor
fittings, solder, brazing rod, nitrogen, or similar fees.)
REFRIGERANTS
• R404A A maximum of $15.00U.S./lb. or $1.00U.S./oz. will be reimbursed.
For factory assistance, call
888-436-5442
or 989-773-7981
Fax 888-779-2040