Warning indicators, faults and remedy
For RC model
Warning indicators
Sound
A lamp
Continu-
ON
ous
Continu-
-
ous
Continu-
ON
ous
Continu-
-
ous
Continu-
Flashing
ous
-
Flashing
-
Flashing
-
Flashing
-
One beep
-
Two beep
High speed ESG (Electronic Safety Governor)
High speed ESG is a device to prevent over revolution of the engine. If the load to the engine becomes light for
some reason, it runs at a higher speed than the usual. In such the case, the buzzer sounds and the ESG is
activated not to ignite the spark plug, therefore, the engine speed varies and be controlled under 6200 min
(rpm).
Low speed ESG
Low speed ESG is a device to prevent the engine from getting damage. If the engine has problems regarding
cooling water, oil pressure, and sensors, the low speed ESG is activated not to ignite the spark plug, and disable
fueling therefore, the engine speed varies and be controlled under 3000 min
Description of faults
ESG
or notice
Normal system test
-
when key on
High
Engine speed exceeds
speed
maximum
ESG
allowable RPM
Low
speed
Low oil pressure
ESG
Low
Cooling water temp. is
speed
high
ESG
Forced
Cooling water temp. is
ideling
abnormally high
Low
speed
Malfunction of sensor
ESG
Malfunction of electrical
-
part
Inform the recommended
timing of engine oil
-
replacement (every
100hrs.)
Lowest idling speed of
-
variable idling system
Highest idling speed of
-
variable idling system
PRE-OPERATING PREPARATIONS
Remark
1 second
Approx.
6,200 min-1 (rpm)
Over
85°C/185°F
Over
140°C/284°F
"A lamp" ON 1 sec. and
OFF 1 sec.
"A lamp" ON 1 sec. and
OFF 9 sec.
-1
(rpm).
33
Rem-
edy
1
2
3
6
3
5
5
6
-1

Hide quick links: