Download Print this page

Safety Cable Installation - Monte Carlo Fan Company Cupra 3CPR60 Series Owner's Manual And Installation Manual

Advertisement

7
Place decorative cap and canopy over
lead wires, safety cable and downrod,
and then replace the hanger ball.
Replace the hanger ball with pin and set
screw and tighten securely.
Warning: Make sure the pin is installed
well on hanger ball with downrod.
Note: If the fan to be installed on a slope
ceiling, the decorative cap shouldn't be
installed corresponding to next
installation step.
10
Make wiring connections as indicates
above, using wire connectors provided.
Connect Black wire from fan to Black
(Live) wire from house. Connect White
wire from Fan to White (Neutral) wire from
house. Connect all green grounded wires
to Grounded wire from House. Make sure
that no filaments are outside of the wire
connectors.
© 2020 Monte Carlo Fan Collections
8
Pin
Canopy
Decorative cap
Install ball end of downrod into mounting
bracket opening. Align (engage) slot on
ball with tab on mounting bracket.
Warning: Failure to align slot on ball with
tab may result in serious injury.
Important: If using the angle mount,
make sure open end of mounting bracket
is installed facing the higher point of the
ceiling and make sure the ceiling angle is
not steeper than 20º. Longer downrod
may be necessary allowing the fan blades
to rotate without obstructions.
11
Wall switch
White
Power
Black
supply
Grounded
wires
Grounding/Green
Black
White
After making the wire connections, the wires
should be spread apart with the grounded
conductor and the equipment-grounding
conductor on one side of the outlet box and
ungrounded conductor on the other side of
the outlet box. The splices after being made
should be turned upward and pushed carefully
up into the outlet box.
9
Tab
Lag screw
Slot
For Canadian installation and for USA fan
and light kit combinations over 35 lbs, in
both flush and downrod modes the safety
cable must be installed into the house
structure beams using 3" lag screws,
washers and lock washers provided.
Make sure that when the safety cable is
fully extended the lead wires are longer
than the cable and no stress is placed on
the lead wires.
Note
Safety Cable in the U.S., Do Not Remove
Knockouts In The Outlet Box.
12
Ungrounded
wires
Lift Canopy allowing the 2 studs to
protrude through the canopy, and then
install knurled nuts as shown. Knurled
nuts provided. Tighten the knurled nuts
securely. The canopy should adjust for
any irregularity in the ceiling or Outlet
box.
Attach decorative cap by locating the
screw heads at bottom of the canopy
with grooves on the cap and twist
clockwise until tight.
4

SAFETY CABLE INSTALLATION

Safety cable
Washer
Lock washer
: If Installing The Secondary Support
Decorative
cap
Stud
Knurled
nut
1/2020