Figure 26 Rectifier Wiring Dc Side Switching - Independent Contactor Switching With External Mov - Phase To Phase - KEB COMBISTOP 38 Instruction Manual

Load brake size 9
Hide thumbs Also See for COMBISTOP 38:
Table of Contents

Advertisement

Rectifiers
DC Side – Independent Contactor Switching with external MOV – Phase to Phase
Switching: DC Side
Line Voltage: 400VAC
Line Voltage: 480VAC
F
= Class CC fuse max. 5A
brk
Optional redundant contactor for safety
Figure 26 Rectifier Wiring DC Side Switching - Independent Contactor Switching with External
MOV - Phase to Phase
2021 KEB America, Inc.
©
Rectifier: Half-wave
Input Voltage: 400VAC
Input Voltage: 480VAC
K
= min 600VDC 9A
brk_dc
AC3
K
= min 600VAC 5A AC1
brk_ac
Model Number: 0691010-001U
Coil Voltage: 170VDC
Coil Voltage: 205VDC
MOV: 625Vrms / 1000Vpk / 500J
Installed at the brake