Optional Components and Accessories
5.2 Microswitch
Part Number: 0938270-M01U
Component
Precision Microswitch
Anti-rotation wire
Plunger
Pipeclip and hardware
Table 6 Microswitch Components
Typically a Microswitch is used to detect when the powered-on brake disengages. This
can be used to signal the system that the shaft is free to rotate, or that the motor is free to
engage.
5.2.1 Installation
1. Install the anti-rotation wire (1) onto the magnet, fitting both ends of the wire into the guide
holes (2). This wire keeps the plunger from rotating out of alignment.
2021 KEB America, Inc.
©
Kit Components
Number Included
1
1
1
1
Figure 16 Anti-rotation Wire Attachment
33