Figure 19 Microswitch Wire Attachment; Figure 20 Microswitch Attachment - KEB COMBISTOP 38 Instruction Manual

Load brake size 9
Hide thumbs Also See for COMBISTOP 38:
Table of Contents

Advertisement

Optional Components and Accessories
5. Apply purple LOCTITE to the threads of the two M2 screws (6). Fasten the microswitch to
the magnet housing with the M2 screws and a small flathead screwdriver.
6. Connect the microswitch leads to a digital multimeter (microswitch black to red = normally
open) and set the meter to diode test settings.
The multimeter should read OL indicating there the microswitch is open.
7. Attach the brake power leads to the power supply and power the brake on.
8. Using an 8mm wrench, rotate the plunger upward until it contacts the microswitch and the
multimeter shows the switch is closed.
2021 KEB America, Inc.
©

Figure 19 Microswitch Wire Attachment

Figure 20 Microswitch Attachment

35

Advertisement

Table of Contents
loading

Table of Contents