Rectifiers

7.2 Example Wiring Diagrams

7.2.1

Rectifier Wiring Diagrams.

Specifcation
Max Input Voltage
Rated Current
Max Operating Temperature
Terminal Wire Size
NOTICE
40

Figure 25 Example Rectifier Wiring Diagrams

Required Rectifier Specifications
 Contactors must have a minimum AC-1 rating of 24A or a minimum
AC-3 rating of 9A. An optional MOV may be used for DC coil and
contactor protection for coil voltages ≥ 180VDC.
i
 These diagrams are wiring suggestions. Other wiring solutions are
possible. Please contact KEB America, Inc. for any questions.
Value
500 VAC
1.2A
45°C
2.5mm / AWG 16