Verifying the Package Contents

Hold-down brackets (2)
Grates: DYCT304G (2), DYCT365G (3)
Burner sets: DYCT304G (4), DYCT365G (5)
Gas pressure regulator (1)
Stainless steel cleaner (1)
(stainless steel models only)
If any parts are missing, see the Replacement Parts List
section on page 12 for Dacor Customer Service and
ordering information.

Installing the Cooktop

WARNING
Verify that the power supply meets the specifications
on page 3 before proceeding.
To prevent damage to the gas pressure regulator,
install it only after the cooktop is mounted in its per-
manent position.
IMPORTANT
Do not over-tighten the hold-down bolts. Over tight-
ening the hold down bolts may result in improper
operation of the dual gas burners.
Do not use a hardening compound or caulk to perma-
nently seal the cooktop into place. The cooktop must
be readily removable if service is required. Removal
of sealant to service the unit will be performed at the
customer's expense.
1. If the cooktop will be used with a downdraft, first install
the downdraft according to the downdraft installation
instructions.
2. Lower the cooktop into the cutout and center it.
3. Secure the cooktop to the countertop using the two (2)
hold-down brackets as shown (included).
Below the Cooktop
8
Installation Instructions
Model DYCT365G/
HPCT365G shown

Connecting the Gas Line

WARNING
Verify that the gas supply meets specifications before
connection. See page 3.
Do not install or use the cooktop without the included
gas regulator installed.
Ensure that the arrow on the regulator points in the
direction of the gas flow, toward the cooktop.
Do not apply excessive pressure when tightening gas
connections and fittings.
Do not use Teflon tape or plumber's putty on flexible
gas line connections.
Before use, test the gas lines for leaks as instructed.
Do not use a flame to check for leaks.
The maximum gas supply pressure to the regulator
must never exceed 1/2 pounds per square inch (psi)
or 3.5 kPa.
The cooktop and shut-off valve must be disconnected
from the gas supply piping system during any pres-
sure testing exceeding 1/2 psi (3.5 kPa).
The cooktop must be isolated from the gas supply
piping system by closing the shut-off valve to the
cooktop during any gas supply piping system pres-
sure testing equal to or less than 1/2 psi (3.5 kPa).
For LP gas installations, the LP gas tank must have
its own high-pressure regulator in addition to the
pressure regulator supplied with the cooktop.
Refer to the figure Underneath the Cooktop on the left
while following these gas hookup instructions.
1. Attach the gas pressure regulator (included) to the gas
inlet on the cooktop.
When working in tight space constraints, the regulator
can be installed anywhere between the cooktop and
gas supply/shut-off valve.
For best performance, attach the regulator as close as
possible to the cooktop. This will minimize gas pressure
loss.
2. Connect regulator to the gas supply/shut-off valve with
a minimum 1/2" flexible gas line (not included).
3. Check for gas leaks:
◊ Turn all cooktop control valves to OFF.
◊ Make a soap and water solution or use a gas leak
detector and check all lines and connections for
gas leaks.
* Make sure the gas supply/shut-off valve is ON.
◊ Turn the gas supply/shut-off valve OFF.

Advertisement