Dacor Discovery HPCT304G Installation Instructions Manual page 9

Hide thumbs Also See for Discovery HPCT304G:
Table of Contents

Advertisement

Cutout Dimensions
Countertop Cutout View
Vertical
combustible
surface
C
Countertop Cutout Dimensions
Installation Type
DYCT304G / HPCT304G (no downdraft)
DYCT304G / HPCT304G (with ERV3015 or PRV30)
DYCT304G / HPCT304G (with RV30)
DYCT365G / HPCT365G (no downdraft)
DYCT365G / HPCT365G (with ERV3615 or PRV36)
DYCT365G / HPCT365G (with RV36)
3/8" min. (1.0 cm)
required for downdraft
cap clearance
Stiffener
or HPCT Gas Cooktop
3/8" min. (1.0 cm) space
behind downdraft
to clear stiffener
ERV or PRV Series
Downdraft: check
downdraft specifications
to determine correct fit
Cooktop with Downdraft: ERV/ PRV Series
Installation Specifications
Rear
wall
D
1 7/8" min.
(4.8 cm)
Countertop
23 3/8" (59.4 cm)
DYCT Gas Cooktop
Cabinet face
Floor
4 1/4" (10.8 cm) min.
from mounting surface to
combustibles below
cooktop chassis
E
F
Min. distance to combustible side
wall above countertop (both sides)
(C) Minimum
2 7/8" (7.3 cm)
19 3/4" (50.2 cm)
3/8" (1.0 cm)
22 1/2" (57.2 cm)
5/8" (1.6 cm)
22 1/4" (56.5 cm)
2 7/8" (7.3 cm)
19 3/4" (50.2 cm)
3/8" (1.0 cm)
22 1/2" (57.2 cm)
5/8" (1.6 cm)
22 1/4" (56.5 cm)
Stiffener
Cooktop with Downdraft: RV Series
All tolerances +1/16" -0" (+1.6 mm)
unless otherwise noted.
F
(D)
(E)
27 5/8"
(70.1 cm)
33 3/4"
(85.7 cm)
5/8" min. (1.6 cm)
required for downdraft
cap clearance
23 1/8" (58.7 cm)
DYCT Gas Cooktop
or HPCT Gas Cooktop
Cabinet face
5/8" min. (1.6 cm) space
behind downdraft
to clear stiffener
RV Series Downdraft:
check downdraft
specifications to
determine correct fit
Floor
(F)
7 1/2"
(19.1 cm)
7" (17.8 cm)
Countertop
7

Advertisement

Table of Contents
loading

Table of Contents