7-6. BREAKERS
July 2007
There are two breakers on electric fryers. To reset the breaker,
open the left door and push-up on the plunger of each breaker.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Checking Procedure for Breaker:
Remove left control panel and pull wires from breaker. Using
a multimeter or continuity light, check across terminals; circuit
should be closed. If not, replace breaker (HP# EF02-125).
To replace breaker, use a 9/16" wrench and loosen the nut
securing the breaker from underneath and then pull the breaker
from the control panel area.
7-7
Model LVE-102, 103, 104