Installation - Fetco CBS-52H User Manual

Table of Contents

Advertisement

Keys To A Successful Installation
If not installed correctly by qualified personnel, the brewer may not operate properly and damage may result.
Damages resulting from improper installation are not covered by the warranty.
Here are the key points to consider before installation:
Electrical:
The power switch has a built-in circuit breaker. To reset, turn to the "off" position, and then back to the "on"
position.
The electrical drawing for the brewer is located on the inside of the lower cover.
Plumbing:
This equipment is to be installed to comply with the applicable federal, state, or local plumbing codes.
The water line must be flushed thoroughly prior to connecting it to the brewer to prevent debris from
contaminating the machine.
Verify that the water line will provide at least 1 ¼ gallons per minute before connecting it to the brewer.
Installation Instructions
Brewer Setup
1. Review the Dimensions for the unit you are installing. Verify that the brewer will fit in the space intended for
it, and that the counter or table will support the total weight of the brewer and dispensers when filled.
2. Remove the brewer's legs from inside the brew
baskets. The two back legs have round bases. The
front leg has a semi-round base and must be
positioned as shown. Place the brewer on its back
and screw in the legs.
3. Place the brewer on the counter or stand.
4. When the brewer is in position, level it front to back
as well as side-to-side by adjusting the legs. Make
sure the front leg is in the position shown.
5. Mark the surface of the counter with the location of
the mounting holes in the legs.
6. Drill ¼" diameter holes in the counter and secure the
legs to the counter with bolts and nuts (not included).
7. Remove the lower cover to access the water and
electrical connections.
Server Ring Installation (LUXUS TPD-1.5 dispensers only.)
1. Place a LUXUS TPD-1.5 dispenser in the proper position under each brew basket.
2. Mark the surface of the counter top with the circular outline of the dispenser bottom.
3. Remove the dispenser and place a mark at the exact center of the circle.
4. Drill a ¼" hole in the center of the circle.
5. Insert the threaded stud on the bottom of the server ring into the hole and secure it with the wing nut.
6. To install the server rings away from the brewer, place the dispensers in the desired location and follow
steps 2 through 5.
Top Cover Instructions
1. Remove all screws. The back edge of the top cover fits tightly over
the vents on the back of the brewer. Carefully lift the front of the
cover up and back.
2. Once the cover is at a 45° angle, it can be lifted completely off.
1. To replace the cover, hold the cover at approximately a 45° angle
and place the back edge over the vents on the back of the brewer.
2. Lower the front of the cover while pulling it over the top of the
brewer. The cover should flex slightly. Install all screws.

Installation

(For Qualified Service Technicians Only)
4
FRONT LEG MUST
BE POSITIONED
WITH FLAT SIDES
FACING LEFT AND
RIGHT.
Warning: Legs are to be adjusted for
leveling the brewer only. Do not use
for height adjustment or extend them
higher than necessary.
1
BACK
LEGS
FRONT LEG
1
2
2