Installation; Keys To A Successful Installation; Installation Check List - Fetco CBS-18 User Manual

Coffee brewing systems
Hide thumbs Also See for CBS-18:
Table of Contents

Advertisement

Keys To A Successful Installation

FETCO brewers are rugged and reliable machines that will provide many years of service. However, if not
installed correctly by qualified personnel, the brewer will not operate properly and damage to the brewer may
result. Damages resulting from improper installation are not covered by the warranty.
Here are the key points to consider before installation:
General: Utilize a qualified beverage equipment service technician for installation.
Place the brewer on a level surface.
Do not adjust the thermostat setting unless absolutely necessary. It is set at the factory for optimum
performance- 205°F. It should only be lowered at high altitude installations.
Plumbing: This equipment is to be installed to comply with the applicable federal, state, or local plumbing
codes.
The water line must be flushed thoroughly prior to connecting it to the brewer to prevent debris from
contaminating the machine.
A taste and odor filter is highly recommended for this and all beverage equipment
Verify that the water line will provide at least 2 gallons per minute before connecting it to the brewer.
Electrical: 120 volt units are supplied with appropriate cords and plugs for 15 amp or 20 amp service.
Dual voltage units (120/208-240VAC) are not supplied with a cord or plug. The terminals must be wired as
follows:
L-1: 120 VAC
L-2: neutral (white)
Both neutral (white) and ground (green) must be provided.
The electrical drawing for is located at the back of this manual and inside the rear cover of the brewer.

Installation Check List

The installation must comply with applicable federal, state, and local codes having jurisdiction at your location.
Check with your local inspectors to determine what codes will apply to the installation and operation of FETCO
products.
1. Review the Dimensional Drawings and the Operating Procedures for the unit you are installing. Verify
the brewer will fit in the space intended for it. Verify that the counter or table will support the weight of
the brewer and servers when filled and that the surface is level.
2. Verify that the actual voltage at the electrical service connection is compatible with the specifications on
the brewer's serial number plate. Make sure the electrical service includes neutral. Ensure at this time
that the circuit breaker to the brewer and the power switch on the brewer are in the off position.
3. Remove the white plastic protective coating from the brewer body.

Installation

(For Qualified Service Technicians Only)
Located on the
control board
3
L-3: 120 VAC
Located next to
the control board.
ground (green)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents