Service Guide To A Successful Installation; Wiring Diagrams - Fetco CBS-2100XTS Users Manual And Operator Instructions

Extractor touch screen
Table of Contents

Advertisement

General:
1. If not installed correctly by qualified personnel, the brewer will not operate properly and damage may result
2. Select and install legs. Leg sets are shipped inside the brew basket
3. Some FETCO CBS-2100XTS series equipment have user configurable dispenser locator-see instructions.
4. Utilize only qualified beverage equipment service technicians for service and installation.
5. Always have an empty dispenser under sprayhead of all coffee brewing equipment-including when at idle
6. Damages resulting from improper installation are not covered by the warranty, and will void the warranty.
Below are the key points to consider before installation:
Electrical:
1. All CBS_Series brewers require an electrical ground wire. Installation without grounding is dangerous.
2. Note Equipotentiality Terminal, if present,
of equipment or of a system to the same potential, not necessarily being the earth (ground) potential, e.g. for local bonding.)
3. Verify voltages, polarity, circuits, and circuit breaker access before attaching equipment.
4. Brewers in this series wire differently in regards to a nuatral wire. Review the wire diagrams.
5. The electrical diagram is located in the Users Guide and online at www.fetco.com.
6. Make sure of the tight grounding of the equipment and use the external ground bolt.
7. The installation must comply with applicable federal, state, and local codes having jurisdiction at your location.
Check with your local inspectors to determine what codes will apply.
CBS-2141XTS From Factory
120 volt models
NEMA PLUG CONFIGURATION
G
G
W
W
NEMA 5-15P
NEMA 5-20P
All CBS 2141XTS
SKU E214171, E214172; E214173
As supplied from factory
Go to fetco.com for the latest version of all information Part B

Service Guide to a Successful Installation

(For Qualified Service Technicians Only)
(To identify the terminals which, when connected together, bring the various parts
.SEE WIRING DIAGRAMS AT BACK OF THIS GUIDE
CBS-2141XTS *Field installed option
120/208-240 volt models
OPTIONAL 2 HEATER ONLY
SKU E214171, E214172; E214173
Showing optional user configuration
page 4
P130 partB REV 003 Technical Supplement July, 2019