Inspection
KEEP INSTRUCTIONS AVAILABLE FOR REFERENCE. Record Date of First Use.
Prior to EACH use, inspect G-Link SRLs for deficiencies, including, but not limited to, corrosion, deformation,
pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating, alteration, broken
stitching, fraying, bird-caging, and missing or illegible labels. Inspect full length of lifeline. IMMEDIATELY
remove G-Link SRL from service if defects or damage are found, or if exposed to forces of fall arrest.
Prior to EACH use, check G-Link SRL lifeline retraction by pulling out a minimum 4' and allowing it to retract
under light tension; lifeline must retract completely. Pull lifeline sharply to test braking function; brakes must
engage. Check shock pack for signs of deployment and/or fall arrest indicator for signs of activation.
IMMEDIATELY remove from service if G-Link SRL does not function properly, or if any evidence of exposure to
forces of fall arrest exists.
Ensure that applicable work area is free of all damage, including, but not limited to, debris, rot, rust, decay,
cracking, and hazardous materials. Ensure that selected work area will support the application-specific
minimum loads set forth in this instruction manual. Work area MUST be stable.
Every 6 months, a Competent Person other than the user must inspect G-Link SRLs. Competent Person
inspections MUST be recorded in inspection log in instruction manual and on equipment inspection
grid label. The Competent Person must sign their initials in the box corresponding to the month and
year the inspection took place.
During inspection, consider all applications and hazards G-Link SRLs have been subjected to.
Inspection Log
Date of First Use: __________________.
Product lifetime is indefinite, as long as product passes all inspection requirements. User must inspect
prior to EACH use. Competent Person other than user must complete formal inspection at least every
6 months. Competent Person to inspect and initial.
This inspection log must be specific to one G-Link SRL. Separate inspection logs must be used for
each G-Link SRL. All inspection records must be made visible and available to all users at all times.
If equipment fails inspection IMMEDIATELY REMOVE FROM SERVICE.