SET TIME OF DAY
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using L or M buttons. AM/
PM toggles after 12. Press NEXT to go to step 3.
Step 3 - Current Time (minutes): Set the minutes of day using L or M buttons.
Press NEXT to exit Set Clock. Press REGEN to return to previous step.
Power Loss - If the power goes out for less than two hours, the system will
automatically reset itself. If an extended power outage occurs, the time of day
will flash on and off which indicates the time of day should be reset. The system
will remember the rest of the program settings. Do not forget to reset for daylight
savings time.
Figure 8
INSTALLER DISPLAYS/SETTINGS
STEP 1
Step 1 - Press NEXT and L simultaneously for 3 seconds.
Step 2 - Hardness: Set the amount of total compensated hardness in grains
(hardness as calcium carbonate) per gallon using L or M buttons. The default is
20 with value ranges from 1 to 150 in 1 grain increments. Note: The grains per
STEP 2
gallon should be increased if soluble iron needs to be reduced.
hardness for each ppm of iron present. If this display shows nA -, then system is
either set-up in "time clock" or "filter" modes. (See table 6, page 19). Press NEXT to
go to Step 3. Press REGEN to exit Installer Displays/Settings.
Step 3 - Day Override: This sets the number of days between regenerations. If
value set to "oFF" regeneration initiation is based solely on gallons used. If value
is set as a number (allowable range from 1 to 28) a regeneration initiation will be
called for on that day even if sufficient number of gallons were not used to call for
a regeneration. Set Day Override using L or M buttons:
STEP 3
• number of days between regeneration (1 to 28); or
• "oFF"
NOTE: If softener is set up as a time clock system (ie: not meter initiated) this
value will be the days between regenerations.
See table 6, page 19, for more detail on softener setup. Press NEXT to go to
step 4. Press REGEN to return to previous step.
STEP 4
Step 4 - Next Regeneration Time (hour): Set the hour of day for regeneration
using L or M buttons. AM/PM toggles after 12. The default time is 2:00 a.m.
This display will show "REGEN" on 0 GAL if system is set for immediate
regeneration. See table 6, page 19. Press NEXT to go to step 5. Press REGEN
to return to previous step.
Step 5 - Next Regeneration Time (minutes): Set the minutes of day for
regeneration using L or M buttons. This display will not be shown if system is
set for immediate regeneration. Press NEXT to exit Installer Displays/Settings.
STEP 5
Press REGEN to return to previous step.
Figure 9
Add 3 grains of