TABLE 4 - BACKWASH NORMAL LENGTH SOFTENER
Grains Capacity/Lb NaCl
6000 to 3501
Backwash Normal
Regenerate
Backwash Normal
Rinse
Total
TABLE 5 - BACKWASH LONGER LENGTH SOFTENER
Grains Capacity/Lb NaCl
6000 to 3501
Backwash Normal
Regenerate
Backwash Normal
Rinse
Total
Regeneration
Reserve
Type
Gallons
AUTO
NORMAL
AUTO
NORMAL
20 to
NORMAL
50,000
oFF**
NORMAL**
20 to
NORMAL
50,000
On 0
AUTO
20 to
On 0
50,000
AUTO
NORMAL on 0
NORMAL on 0*
AUTO*
20 to
NORMAL
50,000
* Factory settings in bold
** These settings are used for time clock systems
All manuals and user guides at all-guides.com
Down Flow Softener* Factory Settings
3500 to 2501
6
8*
45
60*
3
8*
3
4*
57
80*
Down Flow Softener
3500 to 2501
8
10
45
60
8
10
4
6
65
86
TABLE 6 - PROGRAMMING OPTIONS
Days
Override
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve capacity at
oFF
the next Regen Set Time.
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
1 to 24
falls below the reserve capacity or the specified number of days between
regenerations is reached.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
oFF
reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number
1 to 24**
of days between regenerations is reached.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
1 to 24
reaches 0 or the specified number of days between regenerations is reached.
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
oFF
Time of regeneration will not be allowed to be set because of regeneration will
always occur when gallons capacity reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
oFF
Time of regeneration will not be allowed to be set because regeneration will
always occur on 0.
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve
oFF
capacity at the next Regen Set Time or regeneration occurs immediately after
10 minutes of no water usage when gallon capacity reaches 0.
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity
1 to 24
falls below the reserve capacity or the specified number of days between
*14
regenerations is reached or regeneration occurs immediately after 10
minutes of no water usage when gallon capacity reaches 0.
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when specified number of
1 to 24
days between regenerations is reached or regeneration occurs immediately
after 10 minutes of no water usage when gallon capacity reaches 0.
2500 to 1700
6000 to 3501
8
---
75
45
10
6
6
3
99
54
2500 to 1700
6000 to 3501
12
---
75
45
12
6
8
3
107
54
Up Flow Softener
3500 to 2501
2500 to 1700
---
---
60
75
10
12
4
6
74
93
Up Flow Softener
3500 to 2501
2500 to 1700
---
---
60
75
12
14
4
6
76
95
19