ITEM NO.
DESCRIPTION
ORDER NO.
1
15-H4615
Elbow Locking Clip
2
15-PKP10TS8 Polytube Insert, 5/8"
3
15-V3192
Nut, 3/4" Drain Elbow
4-6
15-V3158-01
Drain Elbow 3/4" Male Assy
4-6
15-V3158-02
Drain Elbow 3/4" Male Assy-No Vent Optional
5
15-V3163
O-ring 019
6
15-V3159-01
DLFC Retainer Assy.
7
15-V3162-007 DLFC 0.7 gpm for 3/4"
15-V3162-010 DLFC 1.0 gpm for 3/4"
15-V3162-013 DLFC 1.3 gpm for 3/4"
15-V3162-017 DLFC 1.7 gpm for 3/4"
15-V3162-022 DLFC 2.2 gpm for 3/4"
15-V3162-027 DLFC 2.7 gpm for 3/4"
15-V3162-032 DLFC 3.2 gpm for 3/4"
15-V3162-042 DLFC 4.2 gpm for 3/4"
15-V3162-053 DLFC 5.3 gpm for 3/4"
15-V3162-065 DLFC 6.5 gpm for 3/4"
15-V3162-075 DLFC 7.5 gpm for 3/4"
15-V3162-090 DLFC 9.0 gpm for 3/4"
15-V3162-100 DLFC 10.0 gpm for 3/4"
Systems are shipped without 3/4" nut for drain elbow (polytube
installation only) and 5/8" polytube insert (polytube installation only).
See System Specifications DLFC on page 18, for correct DLFC
size for your unit.
ITEM NO.
ORDER NO.
DESCRIPTION
1
15-H4615
Elbow Locking Clip
2-8
15-V3008-02
Drain Ftg, 1" Straight Assy.
3*
15-V3166
Drain Ftg Body, 1"
4*
15-V3167
Drain Ftg Adapter, 1"
5*
15-V3163
O-ring 019
6*
15-V3163
Split Ring
7*
15-V3151
Nut, 1" QC
8*
15-V3105
O-ring 215
9
15-V3190-090
DLFC 9.0 gpm for 1"
15-V3190-100
DLFC 10.0 gpm for 1"
15-V3190-110
DLFC 11.0 gpm for 1"
15-V3190-130
DLFC 13.0 gpm for 1"
15-V3190-150
DLFC 15.0 gpm for 1"
15-V3190-170
DLFC 17.0 gpm for 1"
15-V3190-200
DLFC 20.0 gpm for 1"
15-V3190-250
DLFC 25.0 gpm for 1"
See System Specifications DLFC on page 18, for correct DLFC size for
your unit.
The nuts and caps are designed to be unscrewed or tightened by hand or
with the special plastic wrench. If necessary a pliers can be used to
unscrew the nut or cap. Do not use a pipe wrench to tighten or loosen nuts
or caps. Do not place screwdriver in slots on caps and/or tap with a
hammer.
Do not use pipe dope or other sealants on threads. Teflon tape must be
used on threads of the 1" NPT connection and on the threads for the drain
line connection. Teflon tape is not necessary on the nut connection nor
caps because of o-rings seals.
All manuals and user guides at all-guides.com
DRAIN LINE - 3/4"
QTY.
1
Optional
Optional
1
1
1
1
One
DLFC
must
be used
if 3/4
fitting
is used
DRAIN LINE - 1"
QTY.
1
1
1
1
1
1
1
1
One
DLFC
must be
used if
1" fitting
is used

Rounded Edge
This Side
Rounded Edge
This Side
Figure 18