Demounting The Bare Shaft Kit - Bredel APEX 10 Original Instructions Manual

Table of Contents

Advertisement

4.3

Demounting the Bare Shaft Kit

When the bare shaft kit is demounted the
pumphead will come loose from the
support set. The pumphead must be
supported in some way, or the pumphead
has to be tipped to the front. In the latter
case piping has to be disconnected and
lubricant has to be removed first.
In this manual it is assumed that the
pumphead will be tipped to the front.
1.
Close any shut-off valves in the suction and
discharge lines and disconnect these lines.
Refer to the manual of the pump.
2.
Remove the lubricant from the pumphead.
Refer to the manual of the pump.
3.
Use a hoist to turn over the pump and put it on
blocks.
4.
Demount the bare shaft kit (A) by loosening
fasteners (B).
MAINTENANCE
A
B
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Apex 15Apex 20