Attaching a Fiber Optic Cable
1. Remove the protective caps from the end of the fiber optic cable.
2. Gently slide the fiber optic cable into the SFP+ module until it clicks into place.
3. Check the LEDs on the switch. When the switch is operating correctly, the green
link LED is lit. For information about the status of the switch LEDs, see
the Information Panels, LEDs, and External Ports" on page
Disconnecting a Fiber Optic Cable
1. Squeeze the release tabs and gently pull the fiber optic cable from the module.
2. Replace the protective caps on the ends of the fiber optic cable.
© Copyright Lenovo 2016
Attention: To avoid damage to the fiber optic cable, follow these guidelines:
Do not route the cable along a folding cable-management arm.
When you attach the cable to a device on slide rails, leave enough slack in the
cable so that it does not bend to a radius of less than 38 mm (1.5 in.) when the
device is extended or become pinched when the device is retracted.
Route the cable away from places where it can be snagged by other devices in
the rack.
Do not overtighten the cable straps or bend the cables to a radius of less than 38
mm (1.5 in.).
Do not put excess weight on the cable at the connection point. Make sure that the
cable is well supported.
To connect the fiber-optic cable to the SFP+ module, complete the following steps.
To disconnect the fiber optic cable from an SFP+ module, complete the following
steps:
Fiber-optic
cable
Protective cap
Chapter 2: Installing and Removing the SI4091