Supermicro SYS-X11SPi-TF User Manual page 42

Table of Contents

Advertisement

Super X11SPi-TF User's Manual
Power Fail LED
The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table below
for pin definitions.
Overheat (OH)/Fan Fail
Connect an LED cable to pins 7 and 8 of the Front Control Panel to use the Overheat/Fan
Fail LED connections. The LED on pin 8 provides warnings of overheating or fan failure.
Refer to the tables below for pin definitions.
OH/Fan Fail Indicator
Status
State
Off
On
Flashing
PWR
Power Button
Reset
Reset Button
3.3V
UID LED
3.3V Stby
3.3V Stby
3.3V Stby
3.3V Stby
NMI
Power Fail LED
Pin Definitions (JF1)
Pin#
Definition
5
3.3V
6
PWR Supply Fail
Definition
Normal
Overheat
Fan Fail
1
2
Ground
Ground
Power Fail LED
OH/Fan Fail LED
NIC2 Active LED
NIC1 Active LED
HDD LED
PWR LED
Ground
19
20
OH/Fan Fail LED
Pin Definitions (JF1)
Pin# Definition
7
Blue LED
8
OH/Fan Fail LED
1. Power Fail LED
2. OH/Fan Fail LED
1
2
42