DO NOT operate the heater without the cover.
8
DO NOT use a naked flame to try and ignite the heater.
8
DO NOT use the heater near flammable, combustible or explosive materials - liquids, solids or gases.
8
DO NOT leave the heater unattended whilst in use.
8
DO NOT obstruct the air inlet and outlet sections of the heater. Keep immediate area clean and tidy.
8
DO NOT point the heater towards the gas cylinder.
8
DO NOT cover the heater whilst in use or immediately afterwards if not cooled off.
8
Keep children and vulnerable people away from the heater.
9
Keep the heater clean and in good working order.
9
Ensure that the heater is correctly turned off and the gas source isolated when not in use.
9
When not in use for any length of time, store heater in a safe, dry, childproof location.
9
NOTE: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
2. INTRODUCTION
Many users have found the advantages of propane heaters far outweigh the small additional running costs, as the fuel is more completely
burned and does not leave an oily residue as experienced with paraffin, kerosene or diesel heaters. There is no odour, except for the few
seconds during start-up and the units run a little more quietly since they do not need a compressor to drive the fuel to the burner. Durable
paint finish. Fan assisted, fitted with a piezoelectric ignition system for trouble-free starting and features a direct gas head assembly. Features
safety solenoid preventing the unit from leaking gas without first being electrically started. Supplied with an approved propane gas regulator
and hose. To run cordless requires compatible 20V battery and mains charger, sold separately. CP20VBP4 (4Ah), CP20VBP6 (6Ah),
CP20VMC (Mains Charger). Tested and certified to CE/EN standards. Manufactured to BS EN 1596.

3. SPECIFICATION

MODEL NO. ................................................................ LP69C
Output ....................................................30,000-68,000Btu/hr
Airflow ........................................................................ 294cfm
Appliance category ................................................... I
Fuel consumption ............................................ 0.65-1.45kg/hr
Gas type: ..................................................................Propane
Gas supply pressure ................................................ 700mbar
IP rating ......................................................................... IPX4
Power ..............................................................................17W
Supply ..............................................................................20V
Electrical fuse rating ...........................................................3A
Heated area ................................................................. 350m³

4. INSTALLATION

NOTE: If a small gas cylinder is used, the heater may not operate at maximum efficiency. It is recommended to use two or more
cylinders linked in parallel, to achieve maximum continuous efficiency.
4.1.
CONNECTIONS
4.1.1.
Check heater and gas cylinder to ensure that they are both in good condition. If not, stop and contact your supplier immediately.
4.1.2.
Site the heater and gas cylinder in the location to be heated.
4.1.3.
Connect the heaters mains charger to an electrical supply outlet, ensuring that both units are earthed correctly or insert battery.
4.1.4.
Connect the gas supply hose to the pressure regulator, and connect the regulator to the gas cylinder. Note: Left hand threads are used
on these fuel gas fittings.
4.1.5.
Connect the other end of the gas supply hose to the heater's gas inlet connection (fig.2). Ensure all connections are tight.
4.1.6.
Gradually open the tap of the gas cylinder. Check hose and all fittings for gas leaks. Close gas tap if gas is present.
WARNING! DO NOT USE A NAKED FLAME to check for leaks, we recommend the use of a foamy soap solution.
4.2.
Locate heater such that the rear intake is at least 2.5m from the nearest obstruction, there is at least 2m space on each side and a
minimum of 3.5m of space in front of it (fig.1)
IMPORTANT: To ensure continuous ventilation to the heater area, a ventilation opening must connect to the outside of the premises where the heater is to
operate. The opening must be 100cm
Min 2.0m
Min 3.5m
fig.1
© Jack Sealey Limited
, I
3B/P
3P
for every kW, and must be set at an equal distance from the upper and lower parts of heater operating area.
2
Min 2.5m
Min 2.0m
Original Language Version
Min 2.0m
LP69C
fig.2
Issue 2 (3)
06/07/21

Advertisement