FIBARO FGWPA-111 Operating Manual page 18

Wall plug
Hide thumbs Also See for FGWPA-111:
Table of Contents

Advertisement

18
i
NOTE
The alarm may be can-
celed by pressing and
holding the button.
ADvAnCED PARAMETERS
32. Alarm state duration
This parameter specifies the duration of alarm state. If a device send-
ing an alarm frame through the Z-Wave network sets alarm duration as
well, this settings are ignored.
Available settings: 1-32400 (in seconds)
600 (10min) Parameter size:
Default setting:
COLOR SETTINGS
40. Power load for violet color
This parameter determines maximum active power value, which when
exceeded, causes the LED frame to flash violet. Function is active only
when parameter 41 is set to 1 or 2.
Available settings: 1000-18000 (100.0-1800.0W, step 0.1W)
Default setting:
18000 (1800W) Parameter size:
41. LED frame color when controlled device is on
When set to 1 or 2, LED frame color will change depending on active
power and parameter 40. Other colors are set permanently and do
not depend on power consumption.
Available settings: 0 - illumination turned off completely
1 - color changes smoothly depending on ac-
tive power
2 - color changes in steps depending on active
power
3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow
8 - cyan, 9 - magenta
1
Default setting:
42. LED frame color when controlled device is off
This parameter defines the illumination color after turning off.
Available settings: 0 - illumination turned off completely
1 - LED frame is illuminated with a color corre-
sponding to the last measured power, before
the controlled device was turned off
3 - white, 4 - red, 5 - green, 6 - blue, 7 - yellow
8 - cyan, 9 - magenta
0
Default setting:
2 [bytes]
2 [bytes]
1 [byte]
Parameter size:
1 [byte]
Parameter size:

Advertisement

Table of Contents
loading

Table of Contents