ic reports in the Z-Wave controller.
The Wall Plug reports the power load with specified frequency. Below
configuration parameters allow to specify how frequently power load
will be reported.
11. Power reporting
This parameter determines the minimum percentage change in active
power consumption (in relation to the previously reported) that will
result in sending new power report.
Available settings: 0 - power reports inactive
1-100 - power change in percent
Default setting:
0
12. Energy reporting threshold
This parameter determines the minimum change in energy consump-
tion (in relation to the previously reported) that will result in sending
a new report.
Available settings: 0 - energy reports inactive
1-500 (0.01-5kWh, step 0.01kWh) - threshold
Default setting:
0
13. Periodic power reporting
This parameter defines time period between independent reports
sent when changes in power load have not been recorded or if chang-
es are insignificant. By default reports are sent every hour.
Available settings: 0 - periodic reports inactive
30-32400 (in seconds)
Default setting:
1800
14. Periodic energy reporting
This parameter defines time period between independent reports
sent when changes in power load have not been recorded or if chang-
es are insignificant. By default reports are sent every hour.
Available settings: 0 - periodic reports inactive
30-32400 (in seconds)
Default setting:
1800
15. Measuring energy consumed by the Wall Plug itself
This parameter determines whether power metering should include
the amount of power consumed by the Wall Plug itself. Results are
being added to the value of power consumed by controlled device.
Available settings: 0 - function inactive
1 - function active
Default setting:
0
Parameter size:
1 [byte]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
1 [byte]
15
i
NOTE
Parameter 11 is not
relevant for loads un-
der 5W.
i
NOTE
In extreme cases, re-
ports may be sent
every second if rapid
and significant load
power changes oc-
cur. Frequent report-
ing may overload the
Z-Wave network so
these parameter's set-
tings should reflect
significant changes in
power load only.
ADvAnCED PARAMETERS