26. THRESHOLD UP value - „On/Off (Power)" association group (3)
The value of BASIC SET command frame sent to the devices associat-
ed in 3rd group „On/Off (Power)" if power exceeded value of param-
eter 21.
Available settings: 0-99 or 255
255
Default setting:
27. THRESHOLD DOWN value - „On/Off (Power)" association
group (3)
The value of BASIC SET command frame sent to the devices associ-
ated in 3rd group „On/Off (Power)" if power dropped below value of
parameter 22.
Available settings: 0-99 or 255
0
Default setting:
ALARMS
30. Active alarms
Define Z-Wave network alarms to which the Wall Plug will respond.
Available settings: 1 - general alarm
2 - smoke alarm
4 - CO alarm
8 - CO2 alarm
16 - high temperature alarm
32 - flood alarm
63 (all)
Default setting:
31. Response to alarm frames
This parameter defines how the Wall Plug will respond to alarms (de-
vice's status change).
In case of values 1 or 2 the Wall Plug is operating normally and LED
frame signals an alarm through time defined in parameter 32 or until
the alarm is canceled.
In case of values 5 to 50 the Wall Plug does not report status change,
power changes, ignores BASIC SET command frames. After time de-
fined in parameter 32 or after the alarm cancellation, connected de-
vice is set to the previous state.
Available settings: 0 - no reaction,
1 - turn connected device on
2 - turn connected device off
5-50 (0.5-5.0s, step 0.1s) - cyclically change de-
vice state with set period
0
Default setting:
2 [bytes]
Parameter size:
2 [bytes]
Parameter size:
1 [byte]
Parameter size:
1 [byte]
Parameter size:
17
ADvAnCED PARAMETERS