Regency U39-NG11 Owners & Installation Manual page 13

Freestanding
Table of Contents

Advertisement

Description
Attic Insulation Shield 12"
Attic Insulation Shield
- Cold Climates 36"
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Extended Vertical Termination Cap
Chimney Conversion Kit A (USA only)
Chimney Conversion Kit B (USA only)
Chimney Conversion Kit C (USA
only)
Wall Firestop
Colinear Flex Connectors
* Olympia Ventis DV applicable for the following units only: B36XTE, B36XTCE, B41XTE, B41XTCE, CV40E, CB40E, CC40E, CV72E, P36, P36E,
RC500E
FPI
946-506/P
Vent Guard (Optional) for AstroCap
**510-994
Rigid Pipe Adaptor (Must use with all rigid piping)
640-530/P
Riser Vent Terminal
** The rigid pipe adaptor is not required on the C34, U39, H15, H27, H35 & RC500E.
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
4" x 6-5/8" Venting
(L)
Run (X)
0" (0mm)
4-7/8" (124mm)
6" (152mm)
8" (203mm)
9" (229mm)
10-1/8" (257mm)
12" (305mm)
12-1/4" (311mm)
24" (610mm)
20-5/8" (524mm)
36" (914mm)
29" (737mm)
48" (1219mm)
37-7/16" (951mm)
Note: Horizontal runs of vent must be level, or have a 1/4" rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.
Selkirk
Simpson
Direct Temp™
Direct Vent Pro
®
46DVA-IS
N/A
N/A@ FPI
N/A
N/A
Disc.
4DT-HKA
46DVA-KHA
4DT-HKB
(Changed Components)
Disc.
4DT-VKC
46DVA-VCH
N/A
N/A
N/A
46DVA-HC
4DT-HHC
46DVA-VC
4DT-HVC
46DVA-08A
4DT-SC
46DVA-F6
4DT-ST14
46DVA-F12
4DT-ST36
46DVA-VSS
4DT-VS
N/A
4DT-VSP
46DVA-SNK14
N/A
N/A
N/A
N/A
N/A
N/A
N/A
46DVA-KCA
N/A
46DVA-KCB
N/A
46DVA-KCC
N/A
46DVA-WFS
N/A
46DVA-ADF
N/A
946-205
946-208/P
946-523/P
946-206
Rise (Y)
13-7/8" (340mm)
16-1/2" (419mm)
18-5/8" (473mm)
20-3/4" (527mm)
29-1/8" (740mm)
37-1/2" (953mm)
45-15/16" (1167mm)
American Metal
Security
Metal-Fab™
Products®
Secure- Vent®
Sure Seal
Amerivent Direct
4DAIS12
N/A
SV4RSA
4DAIS12
N/A
N/A
4DHTK2
4DHTKA
4DHTK1
4DHTKB
4DHTK
4DHTK
N/A
N/A
N/A
N/A
4DHC
4DHT
4DVC
4DVT
4DSC
4DSC
4D12S
4DST14
SV4STC14
4D36S
4DST36
SV4STC36
N/A
4DVS
SV4VS
N/A
N/A
SV4VS
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Vinyl Siding Shield for Riser Vent Terminal
Vent Guard (Optional) for Riser Vent Terminal
AstroCap Horizontal Cap
Vinyl Siding Standoff for AstroCap
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
American Metal Products: www.americanmetalproducts.com
Metal-Fab Sure Seal: www.mtlfab.com
Security Secure Vent: www.securitychimneys.com
Industrial Chimney Company: www.icc-rsf.com
Olympia Ventis DV: www.olympiachimney.com
Regency
U39-11 ULTIMATE™ Freestanding Gas Stove
®
ICC Excel
Olympia
Ventis DV*
Direct
N/A
VDV-AIS04
TM-4AS
N/A
SV-SHK
TM4-HTK
VDV-KW04
SV-HK
TM4-HTK
VDV-K04
SV-FK
N/A
N/A
N/A
TM-4VT
VDV-VCHW04
N/A
TM-4DHT
N/A
SV4CHC-1
TM-4HT
VDV-HC04
SV4CGV-1
N/A
N/A
SV4FC
TM-SC
VDV-SC04
TF-4FA
VDV-F0406
TF-4FB
VDV-SSO
TM-VSS
N/A
N/A
N/A
N/A
TM-4ST14
N/A
N/A
TM-4ST36
N/A
N/A
TM-4DS
N/A
N/A
N/A
N/A
N/A
TM-4CA6
N/A
N/A
TM-4CA7
N/A
N/A
TM-4CA8
N/A
N/A
TM-4TR
VDV-FS04
N/A
N/A
N/A
installation
|
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ultimate u39U39-lp11

Table of Contents