The faults and their causes ........12 Technical data .............. 13 Further information can be found in the following manuals: Page 3 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Note:The fault is indicated when the reservoir is empty, but if the pump element is still surrounded with lubricant. Page 4 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 5
Fig. 2 - Printed circuit board without B/D jumper Power Supply 00002613 Fig. 3 - Printed circuit board without jumper 15/30 Page 5 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 6
- Working hour T - Lubrication cycle tP - Various pause time T1 -Stored pause times T2 -Operating times Page 6 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 7
C - Sequence of the monitoring time D - Readiness for service and fault indication I - Operating time P - Pause time Page 7 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 8
LED is not lit pump stops ope- rating 10012434 Fig. 11- LED display for the monitoring time or fault indication Page 8 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 9
To Remedy to a Fault Important: >2 se- conds. will be lit again at the end of the lubrication cycle. Page 9 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 10
Time ranges: Minutes or hours 20002454 Fig. 14 - Rotary switch - Pause time Switch position Page 10 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 11
2 - Rotary switch 4 - Pushbutton for pause time additional lubrication cycle Repair model M 00 delivered Page 11 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
A - Readiness for service B - Fault indication The external relay drops out, the LED is extinguished. Page 12 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Fault: The pump motor supplies permanently (5 minutes or 30 minutes )- Duration of the monitoring time Cause: Remedy: Technical Data Page 13 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 14
- Lubrication circuit 1 - Lubrication circuit 2 20002460 Fig. 19 - Terminals of the printed circuit board Page 14 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...
Page 15
(min) cation circuits Signal output 1188a95 Page 15 from 15 LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259...