Maximum Cable Lengths / Number Of Fixtures - Acclaim Lighting AL Dot User Manual

Table of Contents

Advertisement

MAXIMUM CABLE LENGTHS / NUMBER OF FIXTURES

The maximum number of fixtures that can be connected in a single series run is 50 when
they are directly connected to each other (which will result in their total cable length being
100 feet (30m):
Where greater distances are required between AL Dots, you can use extra link cables.
However, the total number of AL Dot fixtures must be reduced accordingly so that the total
cable run does not exceed 100 feet (30m).
For instance, if 1' (30cm) link cables were used between each of the AL Dot fixtures, the total
number of fixtures would need to be reduced to 33:
See page 8 if longer runs are needed.
IMPORTANT: In damp or wet location installations, ensure that the output connector
of the final fixture has an end cap fitted [AGDEC] to prevent moisture ingress.
50 fixtures / 100 feet (30m) of total cable length
33 fixtures / 100 feet (30m) of total cable length
www.acclaimlighting.com
7