qs RCP/CNU connector (8-pin)
Used to connect to an MSU-700A/750 Master Setup
Unit, CNU-500/700 Camera Command Network Unit,
or RCP-700-series Remote Control Panel via a CCA-5
Connection Cable. Control signals are sent and
received via this connector. When using an RCP-700-
series unit, power is also supplied.
qd WF MODE (waveform monitor mode output)
connector (4-pin)
Connect to the appropriate connector on a waveform
monitor when monitoring a signal in Sequential mode.
A sequence signal will be output when the SEQ button
on the MSU-700A/750 Master Setup Unit or RCP-
700-series Remote Control Panel is pressed, allowing
simultaneous monitoring of the R, G, and B signals in
Sequential mode. (When both the RCP and MSU are
in use, this connector functions as the output connector
for RCP control.)
For information on these operations, refer to the Master
Setup Unit or Remote Control Panel manual.
qf AC IN (AC power supply input) connector
Use the specified power cord to connect to an AC
power supply. The power cord can be secured to the
HDCU-950 body using an optional plug holder.
SD output block (DIF board)
RC
SD SDI
OUT 1
1 SD SDI OUT 1 and SD SDI OUT 2
SD SDI
connectors
OUT 2
PIX
OUT
2 PIX OUT connector
WF
OUT
3 WF OUT connector
1 SD SDI OUT 1 and SD SDI OUT 2 (SD-SDI
output 1 and 2) connectors (BNC type)
When the system is operating with the field frequency
of 59.94/50 Hz, the signals from the video camera may
be down-converted to SD-component SDI signals and
output from these connectors.
The OUT 2 connector can be assigned for a digital
monitor output that includes character and marker
information.
For information on the setting, contact a Sony service or
sales representative.
2 PIX OUT (picture monitor output) connector
(BNC type)
Used for output of the picture monitor video signal
selected using the RCP-700-series Remote Control
Panel MONITOR SELECT button or the MSU-700A/
750 Master Setup Unit PICTURE MONITOR button.
(When both the RCP and MSU are in use, this
connector functions as the output connector for RCP
control.)
For information on these operations, refer to the Master
Setup Unit or Remote Control Panel manuals.
3 WF OUT (waveform monitor output) connector
(BNC type)
Used for output of the video signal for waveform
monitoring selected using the RCP-700-series Remote
Control Panel's MONITOR SELECT button or the
MSU-700A/750 Master Setup Unit's WF MONITOR
button. (When both the RCP and MSU are in use, this
connector functions as the output connector for RCP
control.)
For information on these operations, refer to the Master
Setup Unit or Remote Control Panel manuals.
Note
The SC phase of the VBS signal output from
connectors 2 and 3 is not locked to the black burst
signal supplied to the REFERENCE connector. Use
the vector monitor in Internal Sync mode.