Parameters description

Some of the following functions may not be available depending on the machine type and access level.
PARAMETER DESCRIPTION
004
To change the measurement unit: 0 = METRIC measurement units / 1 = not available on this model
006
To enable/disable the acoustic signal 0 = buzzer OFF / 1 = buzzer ON
To set the type of hydraulic confi guration for the boiler: 0 = HEATING ONLY - 1 = INSTANTANEOUS FLOW SWITCH - 2 = INSTANTANEOUS FLOW METER
301
3 = STORAGE TANK WITH PROBE - 4 = STORAGE TANK WITH THERMOSTAT
306
To alter the minimum number of fan rotations.
307
To alter the maximum number of fan rotations.
308
To regulate slow ignition.
309
To alter the maximum number of fan rotations in heating mode.
To modify the heating output in heating mode. The factory value for this parameter is 309 but it can be programmed within the range 306 - 309.
310
For more details about the use of this parameter, refer to paragraph "3.12 Range rated".
To confi gure the operation of a supplementary relay (only if board BE09 (accessory kit) is installed) in order to bring a phase (230V AC) to a second heating pump
(supplementary pump) or to a zone valve. The factory value for this parameter is 0, but it can be programmed within the range 0 - 2 with the following meaning:
311
311= 0 - control depends on the confi guration of the wiring of the BE09 board (jumper cut: supplementary pump - jumper present: zone valve)
311= 1 - control of the zone valve
311= 2 - control of the supplementary pump
This parameter is used to reset the operating hours counter in certain conditions (for more details, see "3.13 Faults and reporting, fault A91).
312
The factory value for this parameter is 0. Bring the value to 1 to reset the fl ue gas probe hour counter after the cleaning of the primary heat exchanger.
When the reset procedure has been completed, the parameter will return automatically to 0.
This parameter is used to activate the screed heater function (refer to paragraph "3.7 Screed heater" for more details).
409
The factory value is 0. With the boiler OFF, set the value at 1 to activate the screed heater function on the low temperature heating areas.
The parameter returns automatically to 0 when the screed heater function ends, but the function can be interrupted by manually setting the value at 0.
This parameter is used to modify the forced heating off timer with regards the delay time for re-igniting the burner if it is OFF because the heating temperature has been
410
reached. The factory value for this parameter is 3 minutes but it can be se t within a range from 0 min to 20 min.
This parameter is used to annul the HEAT TIME RESET function and REDUCED MAX. HEATING POWER TIMER, during which the fan speed is limited to a range between
411
minimum and 60% of the max. heating output set, with a 10% increase every 15 minutes. The factory value for this parameter is 0. Bring the value to 1 to reset the timers.
This parameter is used to specify the type of area to be heated. Choose from the following options:
415
0 = HIGH TEMPERATURE (factory setting)
1 = LOW TEMPERATURE
This parameter is used to specify the maximum heating setpoint value that can be set:
range 20°C - 80.5°C, default 80.5°C for high temperature systems
416
range 20°C - 45°C, default 45°C for low temperature systems
NB: the value of 416 cannot be lower than 417.
This parameter is used to specify the minimum heating setpoint value that can be set:
range 20°C - 80.5°C, default 40°C for high temperature systems
417
range 20°C - 45°C, default 20°C for low temperature systems
NB: the value of 417 cannot be higher than 416.
This parameter is used to activate temperature control when the system is connected to an external probe. With the factory value of 0, the boiler always works with a fi xed
418
point. If the parameter is set at 1 and an external probe is connected, the boiler works in thermoregulation mode. If the external probe is disconnected, the boiler always
works with a fi xed point. See paragraph "3.4 Setting the thermoregulation" for more details about this function.
This parameter is used to set the number of the compensation curve used by the boiler in thermoregulation mode.
The factory value for this parameter is 2.0 for high temperature systems and 0.5 for low temperature systems.
419
The parameter can be programmed within the range 1.0 - 3.0 for high temperature systems, or 0.2 - 0.8 for low temperature systems.
See paragraph "3.4 Setting the thermoregulation" for more details about this function.
This parameter activates the "night-time compensation" function. The default value is 0. Set at 1 to activate the function.
420
See paragraph "3.4 Setting the thermoregulation" for more details about this function.
432
Building type
433
External probe reactivity
508
To set the minimum DHW setpoint
509
To set the maximum DHW setpoint
Enabling of special DHW functions: 0 = no function - 1 = fl ow switch/fl ow meter start-up delay
511
2 = with OFF due to overtemperature in DHW mode (with request in progress), the fan is kept at the switch-on speed to reduce the waiting time on restart
3 = absolute DHW thermostats - 4 = smart anti-oscillation DHW function - 5 = all four previous functions active
4.3

INFO menu

iI 0
02
access to info menu
PARAMETER
NAME
I001
Screed heater hours
I002
Delivery probe
I003
Return probe
I004
DHW probe
I005
OT+ DHW setpoint
I008
Flue gas probe
I009
External probe
I010
External temperature for thermoregulation
I011
DHW fl ow rate
I012
Fan rotations
I013
Flow sensor (main zone)
I015
Flue gas probe counter
I016
Delivery setpoint (main zone)
I017
OT+ CH setpoint
I018
System pressure
iI 0
04
or
access to
choise info
parameter value
DESCRIPTION
Number of hours of screed heater function activation
Boiler delivery probe value
Boiler return probe value
DHW probe value with boiler in instantaneous mode
DHW setpoint sent by OT+ remote control to the boiler
Flue gas probe value
Instantaneous external probe value
Filtered external probe value used in the temperature control algorithm to calculate
the heating setpoint
DHW setpoint (only with OT+ connection)
Number of fan rotations (rpm)
Value of the main zone fl ow sensor (when P4.12 = 1)
Number of operating hours of the heat exchanger in "condensing mode"
Delivery setpoint for the main zone
Heating setpoint sent by the OT+ timed thermostat to the boiler
System pressure level
iI 0
05
back to the previous level
15
b
The
a u t o m a t i c a l l y
quits the info
3
01
menu if no key
is pressed for
60 sec.
interface

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ciao 30c2018315120183152

Table of Contents