3) PCB C, filter board
CN8
9
8
PE3
7
6
5
Coding
1
Power supply L2(CN201)
2
Power supply L3(CN200)
Power supply N(CN203)
3
Power supply port of 310VDC(CN212)
4
5
Reserved(CN211)
6
Port for FAN Reactor(CN213)
7
Power supply port for Inverter module(CN214)
8
Ground wire(PE3)
9
Port for communication with PCB B (CN8)
10
CN204
CN213
CN214
CN211
CN203
CN200
CN212
4
3
PCB C 3-phase 12/14/16kW
Assembly unit
11
12
CN205
CN206
PE2
CN30
PE1
CN202
CN201
2
1
Coding
Assembly unit
10
11
12
13
Power supply port for main control board(CN30)
14
Port for ground wire(PE2)
15
Port for ground wire(PE1)
Power supply L1(L1)
16
29
13
14
15
16

Hide quick links: