Ferroli OMNIA M 3.2 Installation And Owner's Manual page 124

Reversible heat pump units for outdoor installation with dc inverter compressor
Hide thumbs Also See for OMNIA M 3.2:
Table of Contents

Advertisement

Available languages

Available languages

9.3.2 1-phase for 4-16kW units
1) PCB A
4-10kW Inverter module
Remarks: for 4-6kw, two capacitors
9
8
Coding
Assembly unit
1
Compressor connection port U
2
Compressor connection port V
3
Compressor connection port W
4
Output port for +12V/9V(CN20)
5
Port for fan(CN19)
2) PCB A 12-16kW
Inverter module
CN502
CN501
10
9
Coding
Assembly unit
1
Compressor connection port U
2
Compressor connection port V
3
Compressor connection port W
4
Port for fan(CN19)
5
Output port for +12V/9V(CN20)
1
2
3
CN20
4
5
7
6
Coding
6
Reserved(CN302)
7
Port for communication with PCB B(CN32)
8
Input port N for rectifier bridge(CN502)
9
Input port L for rectifier bridge(CN501)
/
1
2
3
4
CN19
CN6
8
Coding
6
Port for communication with PCB B(CN32)
7
Port for high pressure switch (CN23)
8
Reserved(CN6)
9
Input port L for rectifier bridge(CN501)
10
Input port N for rectifier bridge(CN502)
25
Assembly unit
/
CN20
5
CN32
6
7
CN23
Assembly unit

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents