Ferroli OMNIA M 3.2 Installation And Owner's Manual page 155

Reversible heat pump units for outdoor installation with dc inverter compressor
Hide thumbs Also See for OMNIA M 3.2:
Table of Contents

Advertisement

Available languages

Available languages

In this case, the setting value of zone 1 is T1S,the setting
value of zone 2 is T1S2.
If you set DOUBLE ZONE and ROOM TEMP. to YES,
meanwhile set WATER FLOW TEMP. to YES or NON,the
following page will be displayed.
Homepage (zone 1)
In this case, the setting value of zone 1 is T1S,the setting
value of zone 2 is T1S2 (The corresponding TIS2 is
calculated according to the climate related curves.)
10.6.6 ROOM THERMOSTAT
About ROOM THERMOSTAT
The ROOM THERMOSTAT is used to set whether the
room thermostat is available.
How to set the ROOM THERMOSTAT
Go to MENU> FOR SERVICEMAN> 6.ROOM
THERMOSTAT. Press OK. The following page will be
displayed:
6 ROOM THERMOSTAT
6.1 ROOM THERMOSTAT
ADJUST
NOTE
ROOM THERMOSTAT = NON, no room
thermostat.
ROOM THERMOSTAT = MODE SET, the wiring
of room thermostat should follow method A.
ROOM THERMOSTAT=ONE ZONE, the wiring of
room thermostat should follow method B.
ROOM THERMOSTAT=DOUBLE ZONE, the
wiring of room thermostat should follow method C
(refer to 9.7.6 "Connection for other
components/For room thermostat")
2
Addition page (zone 2)
(Double zone is effective)
NON
56
10.6.7 Other HEATING SOURCE
The OTHER HEATING SOURCE is used to set the
parameters of the backup heater, additional heating
sources and solar energy kit.
Go to MENU> FOR SERVICEMAN> 7.OTHER HEATING
SOURCE, Press OK. The following page will be dispayed:
7 OTHER HEATING SOURCE
7.1 dT1_IBH_ON
7.2 t_IBH_DELAY
7.3 T4_IBH_ON
7.4 dT1_AHS_ON
7.5 t_AHS_DELAY
ADJUST
7 OTHER HEATING SOURCE
7.6 T4_AHS_ON
7.7 IBH LOCATE
7.8 P_IBH1
7.9 P_IBH2
7.10 P_TBH
ADJUST
10.6.8 HOLIDAY AWAY SETTING
The HOLIDAY AWAY SETTING is used to set the outlet
water temperature to prevent freezing when away for
holiday.
Go to MENU> FOR S ERVICEMAN> 8.HOLIDAY AWAY
SETTING. Press OK. The following page will be
displayed:
8 HOLIDAY AWAY SETTING
8.1 T1S_H.A._H
8.2 T5S_H.A._DHW
ADJUST
10.6.9 SERVICE CALL SETTING
The installers can set the phone number of the local
dealer in SERVICE CALL SETTING. If the unit doesn't
work properly, call this number for help.
Go to MENU> FOR SERVICEMAN>SERVICE CALL.
Press OK. The following page will be displayed:
9 SERVICE CALL SETTING
PHONE NO. 0000000000000
MOBILE NO. 0000000000000
OK
CONFIRM
ADJUST
Press
to scroll and set the phone number. The
maximum length of the phone number is 13 digits, if the
length of phone number is short than 12, please input ,
as shown below:
1/2
5°C
30MIN
-5°C
5°C
30MIN
2/2
-5°C
PIPE LOOP
0.0kW
0.0kW
2.0kW
20°C
20°C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents