Cleaning Intervals

Proper cleaning is critical. To maintain peak performance of the printer, Honeywell
offers a complete line of cleaning products, including pens, cards, films and swabs.
The following table outlines the recommended maintenance schedule for the vari-
ous printer parts.

Maintenance Schedule

Area
Printhead
Platen roller
Peel off roller
RP2/RP4 User Guide
cord to the power supply. Plug into an outlet.
shorten the life of the battery and is not recommended.
Method
(Standard Models)
Cleaning card or cotton
swab with isopropyl
alcohol
Cotton swab
with isopropyl alcohol
Cleaning pens
Method
(Linerless Models)
Cleaning pens
Cleaning pens
Cleaning pens
Interval
After 3-5 rolls of media
After 3-5 rolls of media
After 3-5 rolls of media