The mounting accessory enables the separate housing to be fixed to a wall or to a
horizontal or vertical 2" pipe.
Select a mounting point which is protected from vibration and heat radiation and
where there is sufficient clearance for connecting and calibrating the instrument.
~3.4
b)
a)

3.2 Mounting

The fork of the Soliphant is packed in a cardboard tube for transportation. To prevent
the fork from being damaged, do not remove this until immediately before mounting.
See Section 8.6 "Disposal" for disposing of the packaging.
Before installing, check to see if you have the correct instrument:
Compare the product designation on the nameplate with that given
in the product structure on the next page.
• Soliphant with thread: open-end spanner 1.97 in ~1
• Soliphant with flange: open-end spanner to fit mounting bolts
• Cover lock: Allen key for Allen screws 0.12 in ~
• Clamp for separate housing: Allen key for Allen screws 0.16 in ~
• Dummy plugs for cable glands: Allen key for Allen screws ~
35
and 0.55 in ~
/
" (14 AF)
64
• Flexible metallic protective tubing for connecting cable: open-end spanner 1
(~27 AF)
• Screwdriver, blade width approx. 0.2 in (approx. 5 ... 6 mm)
Endress+Hauser
~4.1
~4.1
ø2"
31
/
" (50 AF)
32
1
/
" (3 AF)
8
5
3
/
" (10 AF)
8
Separate housing for
the electronic insert
3.58
Fig. 6
Separate housing T3
a) Terminal connection area
b) Electronics area for
Unpacking
Instrument identification
Tools
/
" (4 AF)
32
1
/
"
16
3 Installation
electronic insert with
adjusters
11