HN-PTT (Optional) has to be selected instead of removable gooseneck microphone.
Caution:
Space of 1U (1U=44.45mm) should be reserved for cooling.
Blind disks are recommended to seal up the space in the front of cabinet.

Connecting the X-618 System Components

This section describes the connections between the following X-618 system components:

Connecting the Sound Source Equipment to the DCS or NRI

Connecting the DCS to the DA
Connecting the Dry Contacts (Optional)
Connecting the Noise Detector(Optional)
Connecting the X-EOL(Optional)
Connecting the loudspeaker
Connecting DCS, NRI and NPM
Connecting the Sound Source Equipment to the DCS or NRI
Connect the external sound source equipment to the DCS or NRI appliance as necessary.
The sound source connected to the DCS will be used for broadcasting in this device zones .The
sound source connected to the NRI will be used for broadcasting in the all zones of the X-618
system.
X-DCS2000/X-DCS3000 Connecting to the Sound Source Equipment
For DCS Digital Integrated System Manager, there are 3 local auxiliary audio input interfaces, in
which interface 1 uses RCA port, and interface 2 and 3 use XLR port to input balance or non-
balance signal, like microphone and sound console etc. For audio input 1, use cable to connect
audio output and X-DCS3000 input 1. When connecting input 2 and 3 to the external audio source,
pay attention to the connection of interface pin. If it is necessary to use these 2 ports to input non-
balance signal, short circuit the cool end with grounding wire.
Figure 7 Installation Diagram of X-NPM and Extend Key Module
10