PA-5400 Series Firewall Installaon
is connected to a different circuit breaker. This ensures power redundancy and allows for
planned electrical circuit maintenance.
2. Connect the other ends of the DC cables to the front of the DC power supplies by pushing
the plasc connector into the DC power supply unl it clicks into place. Ensure that you
connect each pair of power supplies to a different circuit breaker.
When cabling the DC power supply to your power source, ensure that you route the
cable in such a way that it does not put pressure on the plasc clips located at the
front of the DC power supplies. It is best to route the cables first and then plug the
cables into the power supplies.
STEP 8 |
Confirm that all
STEP 9 |
Aer each AC or DC cable is securely connected, turn on the power source and the
appliance will power on.
Before powering on the firewall, ensure that you have connected your Ethernet cables
in accordance to the mode you wish to boot the firewall in (standard mode or Zero
Touch Provisioning mode) as specified in
PA-5400 Series Next-Gen Firewall Hardware Reference
front slot cards
are properly inserted.
Set Up a Connecon to the
54
Firewall.
2021 Palo Alto Networks, Inc.
©