Maintenance; To Charge Batteries; To Replace Batteries - Minuteman Max Ride 20 Operation Manual

Sweeper vac
Table of Contents

Advertisement

Maintenance

To Charge Batteries:

When the battery / fault gauge reaches the red zone the batteries need to be recharged. Take the machine to a well ventilated
area, unwind the battery charger power cord from the electrical box cover and plug into an appropriate power source. After
approximately 10 seconds the battery charge status indicator will turn on.

To Replace Batteries:

The Max Ride Sweeper Vac contains replaceable batteries. When replacing the batteries, open the back cover, and disconnect
the power to the machine by unplugging the red battery connector. Used batteries that are labelled as recyclable contain
reusable economic goods. These batteries must not be added to the normal waste. Follow all battery manufacturer guidelines
regarding the correct method for disposing of batteries at your location.
For Wet batteries only: Check the battery water levels before each use, refi ll as needed with distilled water.
Caution: DO NOT OVERFILL. Fill water 1/4 " - 1/2" above the separators. Failure to maintain the batteries may result
in battery failures.
WARNING: Charging batteries generates explosive gasses. Do not charge batteries when open fl ames or sparks are
present. Do not smoke. Charge the batteries in a well-ventilated area .
Max Ride Sweeper Vac #988770UM Rev. A 10/21
© 2021 Minuteman International, Inc.
Page 17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr20sw

Table of Contents