Installation Safety Switch - Pilz PSEN ml b 1.1 Operating Manual

Hide thumbs Also See for PSEN ml b 1.1:
Table of Contents

Advertisement

Installation
8.3

Installation safety switch

}
To fix the safety switch at the three possible mounting positions, there are three drill holes
on three sides.
As a result, the safety switch can be installed on the frames of left and right hinged sliding
gates and swing gates. If necessary use a
bracket [
Different holding forces arise, based on the installation.
– Fixing screws in parallel to actuator:
– Fixing screws side-on to actuator:
The tapped holes must have a depth of at least 6 mm.
Installation of safety switch
Fixing screws in parallel/side-on to actuator,
no mounting plate
Fixing screws in parallel/side-on to actuator,
with mounting plate
Fixing screws crosswise to actuator with L-
bracket
Operating Manual PSEN ml b 1.1/2.1/2.2
1003884-EN-12
38]
(see
Order reference: Accessories [
Holding force F
 = 7.500 N,
Zh
Holding force F
 in accordance with EN ISO 14119 = 15.000 N
1max
Holding force F
 = 5.000 N,
Zh
Holding force F
 in accordance with EN ISO 14119 = 10.000 N
1max
INFORMATION
The specified holding forces only apply to installation without mounting
bracket. The holding forces when installed with a mounting bracket can be
found in the table
Mounting plate [
"Technical details for mounting bracket [
Tapped hole
Tapped holes for four M5 screws on the
mounting surface.
Tapped holes for two M8 screws on the
mounting surface, for attaching the mount-
ing plate.
Tapped holes for two M6 screws on the
mounting surface, for attaching the mount-
ing surface
36]
or
Mounting
75]).
72]".
| 35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents