  • Page 1 SDD ES PROFIBUS PSEN sensor technology Operating Manual-1003825-EN-06...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Connection to fieldbus ......................Setting the station address ....................... System structure ........................Operation ..........................Display ............................Structure ........................... Operate menu........................... Menu structure .......................... Menu settings ........................... Device History menu......................... Device Info menu........................Device Event menu........................Operating Manual SDD ES PROFIBUS 1003825-EN-06...
  • Page 4 Contents Dimensions in mm ......................... Technical details ........................Order reference ........................Product ............................. Accessories ..........................EC declaration of conformity ....................Operating Manual SDD ES PROFIBUS 1003825-EN-06...
  • Page 5: Introduction

    SDD ES PROFIBUS Introduction Validity of documentation This documentation is valid for the product SDD ES PROFIBUS. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 6: Overview

    Overview Scope of supply Fieldbus module SDD ES PROFIBUS Unit features SDD ES PROFIBUS is an active subscriber (Master) of Safety Device Diagnostics Backlit display LEDs for – Supply voltage – Fieldbus interface – Safety states and diagnostic information for the safety devices –...
  • Page 7: Front View

    1 – 6: Configurable inputs/outputs for connecting signal inputs/outputs from additional devices (not incorporated in Safety Device Diagnostics) [1] LED Power [2] LED Profibus [3] LED Devices [4] LED Start up [5] LED Fault [6] Display [7] Multifunction switch Operating Manual SDD ES PROFIBUS 1003825-EN-06...
  • Page 8: Safety

    SDD ES PROFIBUS Safety Intended use The SDD ES PROFIBUS is used for communication between connected safety devices and the Profibus DP-V0. The Profibus DP-V0 is designed for data exchange at field level. Application of the product SDD ES PROFIBUS:...
  • Page 9: Use Of Qualified Personnel

    Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). Disposal When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual SDD ES PROFIBUS 1003825-EN-06...
  • Page 10: Function Description

    LEDs indicate the status of the SDD ES PROFIBUS and communication between the safety devices and Modbus/TCP Client. The SDD ES PROFIBUS sends telegrams to the connected safety devices via a ring pro- tocol. The following types of data are transferred to the fieldbus and read in.
  • Page 11: Block Diagram

    NOTICE Damage due to electrostatic discharge! Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive sur- face or by wearing an earthed armband. Operating Manual SDD ES PROFIBUS | 11 1003825-EN-06...
  • Page 12: Commissioning

    9: n.c. n.c. = not connected Please note the following when connecting to PROFIBUS-DP: Only use metal plugs or metallised plastic plugs Twisted pair, screened cable must be used to connect the interfaces Operating Manual SDD ES PROFIBUS | 12 1003825-EN-06...
  • Page 13: Setting The Station Address

    SDD ES PROFIBUS Setting the station address The station address of the SDD ES PROFIBUS is set on the display with the multifunction switch. 1. Press the multifunction switch to change to the menu Settings -> Profibus Config. 2. Make sure that SSA = ON is selected.
  • Page 14: Operation

    SDD ES PROFIBUS Operation The SDD ES PROFIBUS is ready for operation when the "Power" LED is lit and the "Fault" LED is unlit. Legend LED on LED flashes LED off Status Meaning / action Power Supply voltage is outside the permitted range...
  • Page 15: Display

    Press multifunction switch Confirm selection/setting Switch to sub-menu Exit menu: <- Back Rotate multifunction switch up or down Switch menu entries or display potential values Operating Manual SDD ES PROFIBUS | 15 1003825-EN-06...
  • Page 16: Menu Structure

    SSA value via the multifunction switch. Node ID 1-125 Display or change the set Node-ID Restart Trigger a restart of the SDD ES PROFIBUS in order to adopt the amended node configuration settings. Operating Manual SDD ES PROFIBUS | 16 1003825-EN-06...
  • Page 17: Device History Menu

    Number of safety devices (guard locking) = Number of diamonds represented State of the safety devices (guard locking): activated deactivated State of the configurable inputs/outputs Device n/x 1/1 – 16/16 Device n of x connected devices Operating Manual SDD ES PROFIBUS | 17 1003825-EN-06...
  • Page 18 32 minutes. Act.# Actuator short name Ident# (*1) Material number of safety device (*1) Serial number of safety device (*1) Value on restart Operating Manual SDD ES PROFIBUS | 18 1003825-EN-06...
  • Page 19: Device Event Menu

    Device x Number of device Message # x Display of a message or message number (the messages are described in detail under Messages for safety device diagnostics) Dimensions in mm 45 (1,8") Operating Manual SDD ES PROFIBUS | 19 1003825-EN-06...
  • Page 20: Technical Details

    Output of external power supply (DC) Status indicator Display, LED Inputs Number Semiconductor outputs Number Short circuit-proof Semiconductor outputs (standard) Switching capability Voltage 24 V Current 0,04 A Power Fieldbus interface Fieldbus interface Profibus DP-V0 Operating Manual SDD ES PROFIBUS | 20 1003825-EN-06...
  • Page 21 Potential isolation between PROFIBUS and system voltage Type of potential isolation Functional insulation Rated surge voltage 2500 V Mechanical data Mounting position DIN rail Top hat rail 35 x 7,5 EN 50022 Operating Manual SDD ES PROFIBUS | 21 1003825-EN-06...
  • Page 22 1 core flexible 0,25 - 2,5 mm², 24 - 12 AWG Dimensions Height 115 mm Width 45 mm Depth 95 mm Weight 160 g Where standards are undated, the 2016-02 latest editions shall apply. Operating Manual SDD ES PROFIBUS | 22 1003825-EN-06...
  • Page 23: Order Reference

    EC declaration of conformity This/(These) product(s) fulfil the requirements of the low voltage directive 2006/95/EG. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/down- loads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost-...
  • Page 24 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...