Operation
10
Operation
Legend
Status indicators
}
"Device" LED illuminates green: The unit is ready for operation
}
"Safety Gate" LED lights up yellow: Actuator is within the response range
}
"Lock" LED lights up green: Guard locking active
}
"Input" LED lights up yellow: The unit is ready for operation
10.1
Normal operation mlock
Device
Green
Green
Green
Operating Manual PSEN ml b 1.1/2.1/2.2
1003884-EN-12
LED off
LED on
LED flashes (500 ms on, 500 ms off)
LED flashes quickly (50 ms on, 950 ms off)
LED flashes very quickly (25 ms on, 475 ms off)
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
LED status
Safety Gate
Input
Yellow
Yel-
Yel-
Yellow
Yel-
Lock
The safety switch is started
Green
low
Safety gate open, actuator not de-
tected, guard locking deactivated
low
Safety gate closed, actuator detec-
ted, guard locking deactivated
low
Switch status
| 53